Installation Instructions

Document No. 540-568
Installation Instructions
April 10, 2008
Product Numbers
540-110K
Smoke Control Listed Unit Conditioner
Controller Electronic Output
540-110CK Smoke Control Listed Unit Conditioner
Controller Electronic Output with
Secure Mode
CAUTION:
Keep the unit in its static-proof bag until
installation.
Accessories
540–658P25
(pack of 25)
Low cost temporary temperature
sensor that enables space control if
the permanent room or duct sensor is
not installed.
Parts for Smoke Control Compliance
540-155K
Smoke Control Listed Small
Equipment Controller Enclosure
550-002K
Smoke Control Listed Large
Equipment Controller Enclosure
ZBX-XXXX
a
Smoke Control Listed Large
Equipment Controller Enclosure
5041MWCB UL Listed Class 2 transformer
with 120/240/277/480 Vac
50/60 HZ 0.4A primary w/ hub
and 24Vac 50VA secondary w/
hub and circuit breaker
10041MWCB UL Listed Class 2 transformer
with 120/240/277/480 Vac
50/60 HZ 0.5A primary w/ hub
and 24Vac 96VA secondary w/
hub and circuit breaker
KELEAM-2483-OA ULListedClass2Transformer
with primary 120V 60 HZ 0.2A
secondary 24 Vac 30 VA
525-804 Receptacle assembly consisti
ng
of a UL Listed 2x4 junction box
andULListedreceptacle
a. Enclosure part number ZB-X-XXXX, where the rst
X can be 9 or any letter from A to N represents the
type of TEC module installed/to be installed in the
enclosure, and XXXX can be any 4 alphanumeric
characters represent the TEC HVAC application.
For smoke control application, primary
rating is only 120V/ 60 Hz.
Parts for CE Compliance:
550-705
Clamp-on ferrite lter (10 pack)
588-100 series
Approved 2-RJ11 RTS cable in 25’,
50’, or 100’ (7.6-m, 15.2-m, 30.48-m).
Warning/Caution Notations
WARNING:
Personal injury/loss of life may occur if you
do not follow the procedures as specied.
CAUTION:
Equipment damage or loss of data may
occur if you do not follow the procedures
as specied.
Expected Installation Times
10 minutes.
Required Tools and Materials
Electro-Static Discharge (ESD) wrist strap
Flat-blade screwdriver (1/8-inch blade width).
•Smallat-blade screwdriver
Cordless drill/driver set
1/4-inch (6.35 mm) hex nut bit
Prerequisites
Unit Conditioner installed
24 Vac Class 2 power source
Supply power to the unit is OFF
If required, controller enclosure installed
Room temperature sensor installed (optional).
(If desired, a low-cost temporary temperature
sensor is available that plugs into the RTS
port of the TEC (P/N 540-658P25), providing
temperature input and actual space control
until the permanent room or duct sensor is
installed.)
Page 2 of 8 Siemens Building Technologies, Inc.