User Guide
Table Of Contents
- Table of Contents
- How to Use This Manual
- Chapter 1–Program Methodology
- Overview
- Introduction to PPCL
- PPCL Rules
- PPCL Program Design Guidelines
- Relational Operators
- Logical Operators
- Arithmetic Operators
- Arithmetic Functions
- Special Functions
- Order of Precedence
- Resident Points
- Local Variables
- Point Priority Overview
- At (@) Priority Status Indicators
- Point Status Indicators
- Converting a Sequence of Operation intoProgram Code
- Chapter 2–Control OptionComparisons
- Chapter 3–Command Syntax
- Overview
- ACT (Activate lines)
- ADAPTM (Adaptive control, multiple)
- ADAPTS (Adaptive control, single)
- ALARM (Alarm state)
- AUTO (Auto status)
- DAY (Day mode)
- DBSWIT (Dead band switch)
- DC (Duty cycle)
- DCR (Duty cycle routine)
- DEACT (Deactivate lines)
- DEFINE (Define abbreviation)
- DISABL (Disable lines)
- DISALM (Disable alarm)
- DISCOV (Disable COV)
- DPHONE (Disable phone)
- EMAUTO (Emergency, Auto status)
- EMFAST (Emergency, Fast status)
- EMOFF (Emergency, Off status)
- EMON (Emergency, On status)
- EMSET (Emergency, set value)
- EMSLOW (Emergency, Slow status)
- ENABLE (Enable lines)
- ENALM (Enable alarm)
- ENCOV (Enable COV)
- EPHONE (Enable phone)
- FAST (Fast status)
- GOSUB (Go to subroutine)
- GOTO (Go to line)
- HLIMIT (High limit)
- HOLIDA (Holiday)
- IF/THEN and IF/THEN/ELSE (Conditional control)
- INITTO (Initialize totalized value)
- LLIMIT (Low limit)
- LOCAL (Local variable)
- LOOP (Loop control)
- MAX (Maximum value)
- MIN (Minimum value)
- NIGHT (Night mode)
- NORMAL (Normal operating mode)
- OFF (Off status)
- OIP (Operator interface program)
- ON (On status)
- ONPWRT (On after power return)
- PDL (Peak demand limiting)
- PDLDAT (PDL, define load attributes)
- PDLDPG (PDL, digital point group)
- PDLMTR (PDL, meter monitor)
- PDLSET (PDL, setpoints)
- RELEAS (Release)
- RETURN (Return/end subroutine)
- SAMPLE (Sample a statement)
- SET (Set point value)
- SLOW (Slow status)
- SSTO (Start/stop time optimization)
- SSTOCO (SSTO coefficients)
- STATE (State text command)
- TABLE (Table of coordinates)
- TIMAVG (Average over time)
- TOD (Time of day, digital points)
- TODMOD (TOD modes)
- TODSET (Time of day, analog points)
- WAIT (Wait time)
- Overview
- Glossary
- Appendix A—PPCL Reserved WordList
- Index
Control Option Comparisons—Time-of-Day (TOD)
Siemens Building Technologies, Inc. 2-27
APOGEE Interaction with PPCL TOD
APOGEE field panels contain an equipment scheduling application,
which replaces TOD in PPCL. Some portions of TOD programming
are shared by equipment scheduling, specifically the system
calendar.
• Equipment scheduling uses replacement days and special days.
• The R1 replacement day in equipment scheduling corresponds to
the Holiday Schedule in the TODMOD command.
APOGEE PPCL User’s Manual
2-28 Siemens Building Technologies, Inc.