User's Manual

Table Of Contents
User Manual for AyCare AyTerminal
V2.1 AyCare application
72
curr.:
10
Noise
72
curr.:
10
Noise
Figure 4-40 Noise adjustment screen
Possible actions in this screen are:
Increasing or decreasing the threshold value by using the up/down buttons.
Saving the threshold value using the OK button (right button).
Going back to the previous screen without saving any changes using the Back button (left
button).
No validations are made when leaving this screen.
If any problem occurred while saving the noise threshold a message box containing a proper
message will be displayed (e.g. “The value could not be saved. Please try again.” for English
language selected). Otherwise the previous screen is shown without notification.
4.4.4.3Activation delay
Between the moment of activating the mode and activating the noise sensor there can be a delay.
This delay is called Activation delay; it is configurable. The Activation delay can take values
between 0 s and 255 s. This option is useful when some time is needed to place the AyTerminal in
the desired place (e.g. car) after activating the mode.
The activation delay is set using the hh:mm:ss format (255s => “00:04:15”).
00:01:00
Activation delay
OK
0:01:00
Activation d
OK
Figure 4-41 Set activation delay screen
To set the value, enter the time, select OK, and then press the OK button (right button). In this
moment the entered value is validated. If is greater than 255s then the device will play a negative
acknowledgment tone and a message box will be displayed (“Activation delay must be between 0s
and 255. New value denied.” for English language selected). Then the previous screen is
displayed. If the value is correct, a positive acknowledgment tone is played and the previous
screen is shown.
4.4.5Duration
This menu item is used to define the time, for which the mode is set into the alarm state if an alarm
is triggered. If duration is set to 0, the Alarm state is active until the deactivation code is entered.
For Baby Phone mode 0 is not acceptable for duration because there is no siren as a notifier.
4.4.6Overview
This menu item is used to overview the mode settings in a text screen with all set values (see
Figure 4-42).
Page 35 / 50