User's Manual

Table Of Contents
User Manual for AyAlarm AyTerminal
V2.1 AyAlarm application
12:00:
Timer
0
3
2
1
12:00:
Timer
0
2
1
Figure 5-41 Set alarm clock screen
The colons are displayed after the second and fifth digits are inserted. OK option is displayed only
after inserting the time in complete format (hh:mm:ss). To leave this screen and set the value the
user must first select OK option and then press the enter button.
5.4.4.3Ego-motion
The following menu is provided for setting the ego-motion parameter value:
Ego-motion
Threshold
Active
Ego-motion
Threshold
Active
Figure 5-42 Setup ego-motion menu screen
The available buttons and screen’s functionality are the same as in every menu screen.
Note! If the ego-motion trigger is the only trigger for a mode then the “Active” option is missing from
the menu screen (e.g. Baggage Secure mode).
The setup menu allows setting one threshold which is applied to all three axes of the ego-motion
sensor. It is not possible to define a threshold on a combination of different axes, e.g. alarm
triggering on a resulting vector of one or two axes. The alarm is triggered on ego-motion detection
if the default or defined threshold value of the ego-motion sensor is exceeded.
The scale for the axis is 0g to +3,6g in 26 steps (0-100%). One step is 4%.
72
curr
10
Ego-motion
72
curr
10
Ego-motion
Figure 5-43 Set motion sensitivity
Possible actions in each screen are:
Increasing or decreasing the threshold value using the up/ down buttons
Request to save set threshold value using the right button (OK button)
Going back to the previous screen without saving any changes using left button
No validations are made when leaving this screen.
If any problem occurred while saving the data a message box screen containing a proper message
is displayed. The message text is: “The value could not be saved. Please try again”. Otherwise
previous screen is shown without notification.
5.4.4.4Noise
The following menu is provided for setting noise parameters values: