Specifications

Siemens Mobility, Traffic Solutions
Sopers Lane, Poole, Dorset
BH17 7ER
Version 10 Page 60 of 120 Status Issued
Last Editor harry.smyth Date 03 November 2014
Document
Name
GENERAL HANDBOOK FOR HEIMDALL
DETECTORS
Doc. No.
667/HB/31900/000
Copyright Siemens plc 2014 All Rights Reserved
5.6 On Crossing Pedestrian Detector
5.6.1 Performance Details
Operating Range
1
: 4m to 12m.
Crossing Width: 2.4m to 4m.
Crossing Length: Detection system can be adjusted to
accommodate crossing lengths between 4m to
12m.
Detector Locations: A typical system will comprise two Heimdall
detectors located on opposite sides of the
crossing.
Detection Presence Time: Not applicable.
Detector Mounting Height: 3.3m to 4.0m.
Accuracy: Not applicable.
LED Orientation: Facing forwards (reference section 2.3).
5.6.2 Part Number
667/1/31900/05X
Where X is;
0 Basic Detector
1
Basic Detector with RS485 (SiTOS) Serial
Interface
2
2 Basic Detector with Wireless Link Interface
3
3
Basic Detector with a Second Solid-State Relay
Output
4
4
Basic Detector with both a Wireless Link and a
Second Solid-State Relay Output
5
Table 5-21 – Heimdall On Crossing Pedestrian Detector Part Number
1
Standard Alignment
2
This option is non-standard. Please refer to Siemens Poole for further ordering information.
3
This option is non-standard. Please refer to Siemens Poole for further ordering information.
4
This option is non-standard. Please refer to Siemens Poole for further ordering information.
5
This option is non-standard. Please refer to Siemens Poole for further ordering information.