4.5 Mains Transformer
The appropriate transformer is contained with the Outer case specified in Table 4 and
should not be ordered separately. The mains transformers will occupy a position in the
bottom left hand corner of the controller. Please refer to Figure 39, which shows one
transformer fitted to the ST950ELV cabinet. On those occasions when a 20A variant of the
controller is chosen one transformer and one HPU will be provided, to supply the appropriate
load. When a 40A Outercase is specified an additional transformer and HPU Card will
installed, alongside the first transformer and HPU Card. Individual leads from the transformer
will be connected to SKT 3 on the high power to the HPU Card. A loom from the transformer
will be connected into PL5 on the HPU. On those occasions when a 40A Outercase is
specified the corresponding connection from the second transformer will be connected to the
corresponding connections on the second HPU Card. If a 40A controller has been specified
and therefore a second HPU PCB is fitted a four way relay connection cable will be inserted
between PL1 on the first HPU Card and PL2 on the second HPU Card.
The input voltage to the Dimming Transformer can be selected by connecting the input
supply leads to the appropriate terminals. Please refer to the ST950 General Handbook
Please note that a low Inrush version of the ST950 controller is available. Please refer to
Table 4.
Figure 39 – ST950 HPU and Transformer Figure 40 – SKT3
Mains
Transformer
HPU
SKT 3
HPU
PL5
Earth
Common
Dim
Bright