4.9 SLD4 Detector Cards
SLD4 Detector Cards do not form part of the Outer case, chosen from Table 4 and therefore
must be ordered separately. As detailed previous sections, detector cards are inserted into
Intelligent Detector Backplanes. Each Intelligent Detector Backplane will accommodate four
SDL4 Detector Cards. The SDL4 Detector Cards have a facility to communicate with each
other to allow automatic setup. This communication facility uses an infrared link. The infrared
beam travels horizontally between SLD4 cards and therefore only those SLD4 cards that are
mounted alongside each other can utilise this infrared communications technique.
Communications between SLD4 Cards mounted vertically, with respect each out, must be
connected using linking cables. Please refer to Figure 47 which shows the required
connection.
Figure 50 – IDB Optimisation
Important Note
Configuration Engineers should read the notes in the WiMag section regarding
Backplane positioning. Important information on the relationship between SDL4
Cards, the Infrared communication technique between SLD4 cards and the
restrictions this communication technique has on the positioning of Detector Cards is
contained in the that section.