4.11.2 WiMag Loop Detector Replacement Card
Under normal circumstances WiMag Detection signals will be processes by components in
the WiMag system, detailed in section 4.11.1.
However, to allow the minimum amount of equipment to be installed in a controller the
WiMag loop detector replacement card has been developed to provide up to 4
magnetometers.
The WiMag Loop Detector Replacement Card plugs into either an individual detector
backplane or an intelligent Detector Backplane. Configuration Engineers should configure
controllers to ensure that the WiMag Loop Detector Replacement Cards are inserted into
their own Intelligent Detector Backplane or Single Detector Backplane. This is because the
WiMag Loop Detector Replacement Card has particular power requirement that are not
compatible with the SLD4 Detector Cards. Additionally, WiMag Loop Detector Replacement
Cards should not be mounted between SLD4 Cards as this would interrupt the infrared
communications link between SLD4 Cards; referred to in the sections detailing Intelligent
Detector Backplanes and SLD4 Cards.