4.15 Stratos Outstation
This unit is not included in the Outercase ordered from Table 4 and therefore must be
specified separately. Please refer to the family tree document for the Stratos Outstation
(667/DZ/52250/ETC) when specifying the make-up of the unit. Section 4.7 explains the
location the Stratos Outstation unit can take within the ST950ELV cabinet.
Power for the Stratos Outstation can be provided by utilising one of the mini circuit breakers
within the Master Switch Assembly. One mini circuit breaker will be installed for the OTU
(Stratos Outstation); however, a second and third kit may be fitted using kit of parts
667/1/27121/000. Positions for these additional power facilities are shown on
667/GA/27121/000. With reference to Figure 73, mains supply power for the Stratos
Outstation is connected via a standard IEC C13 mains lead. The other boards in the system
are powered over the RJ45 GSPI cables. To provide Lamp Supply monitoring on the Stratos
Outstation the Lamp Supply Monitor Port is used.
Figure 73 - Power for Stratos Outstation Unit
If the internal backup battery is fitted the Stratos Outstation can be mounted in
any orientation apart from front panel facing down.
Mains
Connection
to Stratos
Outstation
Lamp
Supply
Monitor
Port