4.16.2 Additional Regulatory Sign Connection
If the 2nd HPU PCB is not specified and there is a requirement to power more than 8
regulatory signs an expansion kit (667/1/33070/000) is available to support an additional 12
regulatory signs.
With reference to Figure 76 and 77, the expansion kit is positioned above the HPU on the
left hand side of the cabinet. Additional information on the exact position can be sought from
diagram 667/GA/33070/000 Sheet 1. Please Note! The Additional Regulatory Sign Kit
contains both transformer and associated PCB. When specifying multiple kits care
should be taken to ensure that there is sufficient space within the specified cabinet
for the required items.
With reference to Figure 75, the AC input for the ancillary power supply should be obtained
from the master switch unit (Live connected to MCB SW1 and Neutral connected to Terminal
N3). The step down transformer will be configured with conventional power supply leads to
allow this connection. The AC output from the transformer is applied to a terminal strip TB2,
as detailed in the figure below. Please refer to 667/GA/33070/000 Sheet 2 for a detailed
connection scheme and earth arrangement.
Figure 75 – Additional Reg Sign Power
Figure 76 Additional Reg Sign Figure 77 Additional Reg Sign