Lamp monitoring is performed (if required) by LSLS backplane external monitor input
channels. PL1 and PL2 on the Additional Regulatory Sign Kit PCB are four way Molex style
connectors. These current outputs are wired to the LSLS backplane module external
(torroid) inputs, using two twisted pair and provide monitoring signals, if required.
An indication of the connections point is provided in the Figure 78 immediately below. The
full connection scheme should be sought from drawing 667/GA33070/000 sheet 2
Figure 78 – LSLS Monitoring Connections
Please Note Instructions and specific precautions for making the LSLS backplane torroid
connections are detailed the Siemens Type 900 ELV Installation Commissioning and
Maintenance Handbook, 667/HE/32900/000, Paragraph 4.19. Output terminals are
configured using the appropriate software configuration tools (IC4). Please refer to
paragraph 6.15 for information on HPU regularity sign monitoring.