User Manual

BUP2 PROGRAMMER WIRING INTERCHANGE GUIDE
E N L
HW
OFF
CH
OFF
HW
ON
CH
ON
N L 1 2 3 4
2 1 - - 6 10
2 1 8 11 6 10
N L - - 3 4
N L 1 2 3 4
N L 1 2 3 4
*N L 1 2 3 4
N L - - 6 3
N L 7 4 6 3
N L 1 2 3 4
N L 7 4 8 5
N L 3 6 1 4
N L 2 - 3 4
N L 3 6 1 4
2 1 6 9 4 7
N L - - 2 4
N L
HW
OFF
CH
OFF
HW
ON
CH
ON
Siemens, Landis &
Staefa, Landis & Gyr
RWB2/20/40/200/252/
270/XP/9
ACL
MP
FP
2000
112
241/522
722
DRAYTON
TEMPUS 3/4/7
GLOWWORM
Mastermind
HONEYWELL
ST499A
ST699B/ST699C
ST6300A/ST6400C
ST7100
HORSTMANN
525/527
Centaur
TC1/TC7
Diadem/Tiara
Gem
Diamond 423
E N L
HW
OFF
CH
OFF
HW
ON
CH
ON
N L 1 2 3 4
N
1
8
L
2
9
- - 3 4
2
3
1 - -
7
8
4
Siemens, Landis &
Staefa, Landis & Gyr
RWB2/20/40/200/252/
270/XP/9
POTTERTON
411
423/424
*N L 1 2 3 4
Mini-Minder
N L 1 2 3 4
EP2000/3000/2001/
3001/6000
5 6 - - 1 2
DANFOSS RANDALL
102
7
1
6 - - 4 2
3020P
7
1
6 5 3 4 2
3033
7
1
6 - - 4 2
3060
N L 3 6 1 4
Set2/Set5
N
1
6
5 3 4 2
4033
N L 4 2 3 1
701/702
N L 1 4 3 6
922/972
E N L
HW
OFF
CH
OFF
HW
ON
CH
ON
N L 1 2 3 4
•N
1
3
L - - 2 5
3
6
7 4 2 5 1
Siemens, Landis &
Staefa, Landis & Gyr
RWB2/20/40/200/252/
270/XP/9
SANGAMO
409-1
409-3
4
5
3
6
2 7 1 8
410-1
4
5
6 1 2 7 8
410-3
4
5
3 2 7 1 8
414
1 2 8 5 6 3
SUNVIC
DHP 2301
1 2 8 5 7 4
ET1401/1451
N L 1 4 3 6
SP2
N 3 1 4 2 5
SP50
N L 1 425
SP100
4
5
1
3
6
2 7 - 8
410-2
•N
1
3
L -
- 2 5
409-4
E N L
HW
OFF
CH
OFF
HW
ON
CH
ON
N L 1 2 3 4
N L - - 3 2
1 2 - - 4 5
Siemens, Landis &
Staefa, Landis & Gyr
RWB2/20/40/200/252/
270/XP/9
SMITHS INDUSTRIES
Centroller 10/100
Centroller 60/70/90
2 3 - - 4 1
Superswitch
N
2
L - - 3 1
SWITCHMASTER
320
N
2
L - - 3 1
350
N L - - 3 1
400/600
N L 4 2 3 1
800/805/900/905/
9000/9001
N L 3 6 1 4
SONATA SYMPHONY
900/9000/9001
N L 1 2 3 4
Tower DP72
N
2
3
L - - 2 6
T20/30
N
3
L 1 4 2 AS
80M/80PM
N
1
3
L-- 2 AS
80P
N
1
3
4
L - - 2 AS
AMF/VENNER
CHC/W2/80
details shown below. It will be necessary to replace the baseplate unless indicated.
When replacing any of the below with your BOSS programmer follow the connection
On Venner units (AS) terminals x2 if both wired
one goes to CH ON (4) on RWB2 and you will
have to link the remaining (AS) terminal and the
wire on terminal 5 together
Link 5+4 on old unit together in separate
terminal block
*No rewiring necessary fits directly on baseplate
NB When replacing RWB20 by new product a neutral connection to backplate is necessary
(please check)
•Link old 4+6 in separate
terminal block
Wiring of this unit should be carried out by a competent electrician.
While every effort is made to ensure the accuracy of the instructions given, you will appreciate that discrepancies may occur due any of a variety of reasons outside our control.
If after wiring your system you find that it does not work properly you should:
Check that you have used the correct system and wired it correctly. Ensure that no wiring links have been missed and all screws are tight
Check with the helpline on
0870 850 0184, there may be a simple explanation.
As new equipment is introduced we will try to include it as soon as possible, in the interim the information will be made available on request.