2 © Siemens AG 2015 Temperature Measurement 2/2 2/4 2/8 2/15 2/22 2/28 2/35 2/42 Product overview Transmitters for mounting in sensor head SITRANS TH100 two-wire system (Pt100) SITRANS TH200 two-wire system universal SITRANS TH300 two-wire system universal, HART SITRANS TH400 fieldbus transmitter Transmitters for rail mounting SITRANS TR200 two-wire system universal SITRANS TR300 two-wire system universal, HART SITRANS TW four wire system, universal, HART 2/54 2/59 2/68 Transmitters for field mounti
© Siemens AG 2015 Temperature Measurement Product overview ■ Overview Application 2 Mounting of transmitter with Ex protection Page Software for parameterization Transmitter Sensor Zone 2 and zone 1 Zone 2, zone 1 and zone 0 2/4 SIPROM T SITRANS TH200 Zone 2 and zone 1 Transmitters for connection to resistance thermometers, resistance-based sensors, thermocouples and DC voltages up to 1.
© Siemens AG 2015 Temperature Measurement Product overview Application Mounting of transmitter with Ex protection Transmitter SITRANS TW Safe area Transmitters for connection to resistance thermometers, resistance-based sensors, thermocouples, DC voltages and DC currents for: • Four-wire system Page Software for parameterization Sensor Zone 1, zone 0, 2/42 zone 21, zone 20 SIMATIC PDM SITRANS TF280 Transmitter for connection to resistance-based sensor • In field enclosure for heavy industrial use •
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH100 two-wire system (Pt100) ■ Overview ■ Application Used in conjunction with Pt100 resistance thermometers, the SITRANS TH100 transmitters are ideal for measuring temperatures in all industries. Due to its compact size it can be installed in the connection head type B (DIN 43729) or larger. 2 The output signal is a direct current from 4 to 20 mA that is proportional to the temperature.
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH100 two-wire system (Pt100) ■ Technical specifications Input Resistance thermometer Certificates and approvals Explosion protection ATEX EC type test certificate • "Intrinsic gas safety" type of protection Measured variable Temperature Sensor type PT100 to IEC 60751 Characteristic curve Temperature-linear Type of connection 2-, 3- or 4-wire circuit Resolution 14 bit Measuring accuracy • Span <250 °C (4
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH100 two-wire system (Pt100) ■ Selection and Ordering data ■ Dimensional drawings • Without explosion protection 7NG3211-0NN00 • With explosion protection "Intrinsic safety" type of protection and for zone 2 - to ATEX - to FM (cFMUS) 7NG3211-0AN00 7NG3211-0BN00 Further designs Order code 20.8 (0.
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH100 two-wire system (Pt100) ■ Schematics 6 5 4 3 3 5 6 4 3-W 6 4 3-W 3 3 4 Pt100 Two-wire system (parameterizable line resistance) Three-wire system Uaux + 6 4 3-W 3 - 6 5 4 2 5 Pt100 3 6 5 4..
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH200 two-wire system, universal ■ Overview ■ Application SITRANS TH200 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 43729) or larger.
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH200 two-wire system, universal ■ Technical specifications Input Response time 250 ms for 1 sensor with opencircuit monitoring Open-circuit monitoring Always active (cannot be disabled) Short-circuit monitoring can be switched on/off (default value: OFF) Measuring range parameterizable max. 0 ...
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH200 two-wire system, universal 2 Min. measured span 2 mV or 20 mV Certificates and approvals Overload capability of the input -1.5 ... +3.
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH200 two-wire system, universal Digital measuring errors Thermocouples Resistance thermometer Input Input Measuring range Min. measured span Digital accuracy °C / (°F) °C (°F) °C (°F) Pt25 -200 ... +850 (-328 ... +1562) 10 (18) 0.3 Pt50 -200 ... +850 (-328 ... +1562) 10 (18) Pt100 ... Pt200 -200 ... +850 (-328 ... +1562) 10 Pt500 -200 ... +850 (-328 ... +1562) Pt1000 Measuring range Min.
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH200 two-wire system, universal ■ Selection and Ordering data Article No. Temperature transmitter SITRANS TH200 2 for installation in connection head, type B (DIN 43729), two-wire system, 4 ...
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH200 two-wire system, universal ■ Dimensional drawings Mounting on DIN rail Ø 44 (1.73) 2 33 (1.30) (1) st Te (2) 1 + 4...20 mA SIEMENS 1 3 3 2 – (2) 2 6 4 3-W (3) (1) Te st + - 6 5 4 SITRANS TH200, mounting of transmitter on DIN rail 5 (4) 50.5 (1.99) 33 (1.30) 59.6 (2.35) 26.3 (1.04) 14 (0.
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH200 two-wire system, universal ■ Schematics 6 + - 6 5 4 3 3 5 4 4 4 6 + - 6 5 4 5 + TC - 6 + - 6 5 4 Cold junction compensation Internal/fixed value Two-wire system 1) 3 3 5 4 3-W 3-W 4 3 3 R Two-wire system 1) 3 6 5 RTD 3 6 + 5 3-W 4 6 + - 6 5 4 5 RTD 3 3 4 3-W 3 3 3-W 2 Thermocouple Resistance 3-W Resistance thermometer 6 + - 6 5 4 5 + TC - R RTD
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH300 two-wire system, universal, HART ■ Overview ■ Application SITRANS TH300 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 43729) or larger.
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH300 two-wire system, universal, HART ■ Technical specifications Input Response time 250 ms for 1 sensor with opencircuit monitoring Open-circuit monitoring Always active (cannot be disabled) Short-circuit monitoring can be switched on/off (default value: OFF) Measuring range parameterizable max. 0 ...
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH300 two-wire system, universal, HART Open-circuit monitoring Can be switched off Construction Measuring range -10 ... +70 mV -100 … +1100 mV Material Molded plastic Weight 50 g (0.11 lb) Dimensions See "Dimensional drawings" Cross-section of cables Max. 2.5 mm² (AWG 13) Min. measured span 2 mV or 20 mV Overload capability of the input -1.5 ... +3.
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH300 two-wire system, universal, HART Digital measuring errors Thermocouples Resistance thermometer Input Input 2 Measuring range Min. measured span Digital accuracy °C/(°F) °C (°F) °C (°F) Pt25 -200 ... +850 (-328 ... +1562) 10 (18) 0.3 (0.54) Pt50 -200 ... +850 (-328 ... +1562) 10 (18) 0.15 (0.27) Pt100 ... Pt200 -200 ... +850 (-328 ... +1562) 10 (18) 0.1 (0.18) Pt500 -200 ...
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH300 two-wire system, universal, HART ■ Selection and Ordering data Article No. Temperature transmitter SITRANS TH300 for installation in connection head, type B (DIN 43729), two-wire system 4 ...
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH300 two-wire system, universal, HART ■ Dimensional drawings Mounting on DIN rail Ø 44 (1.73) 2 33 (1.30) (1) st Te (2) 1 + 4...20 mA SIEMENS 1 2 – (2) 2 3 6 4 3-W 3 (3) (1) Te st + - 6 5 4 SITRANS TH300, mounting of transmitter on DIN rail 5 (4) 50.5 (1.99) 33 (1.30) 59.6 (2.35) 26.3 (1.04) 14 (0.
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH300 two-wire system, universal, HART ■ Schematics 6 5 4 3 3 5 4 3 5 4 2 6 + - 6 5 4 5 + TC - 6 + - 6 5 4 Cold junction compensation Internal/fixed value Two-wire system 1) 3 3 5 4 3-W 3-W 4 3 R Two-wire system 1) 3 6 5 4 RTD 3 6 + - 3-W 4 6 + - 6 + - 6 5 4 5 RTD 3 3 4 3-W 3 3-W 3 Thermocouple Resistance 3-W Resistance thermometer 6 + - 6 5 4 5 + TC
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH400 fieldbus transmitter ■ Overview ■ Application • Linearized temperature measurement with resistance thermometers or thermal elements • Differential, mean-value or redundant temperature measurement with resistance thermometers or thermal elements • Linear resistance and bipolar millivolt measurements • Differential, mean-value or redundant resistance and bipolar millivolt measurements 2 ■ Function Features •
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH400 fieldbus transmitter System communication Thermocouple to IEC 584 Measuring range • Type B 400 .. +1820 °C (752 ... 3308 °F) • Type E -100 ... +1000 °C (-148 ... +1832 °F) PROFIBUS PA • Type J -100 ... +1000 °C (-148 ... +1832 °F) Segment coupler • Type K -100 ... +1200 °C (-148 ... +2192 °F) • Type N -180 ... +1300 °C (-292 ... +2372 °F) • Type R -50 ... +1760 °C (-58 ...
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH400 fieldbus transmitter Conditions of use Certificates and approvals Ambient conditions 2 Explosion protection ATEX Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) EC type test certificate KEMA 06 ATEX 0264 Permissible storage temperature -40 ... +85 °C (-40 ... +185 °F) • "Intrinsic safety" type of protection Relative humidity 98 %, with condensation II 1 G Ex ia IIC T4...
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH400 fieldbus transmitter ■ Selection and Ordering data Article No. Temperature transmitter SITRANS TH400 for installation in connection head, with electrical isolation, order operating instructions separately. Article No.
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH400 fieldbus transmitter ■ Dimensional drawings 2 s 2 1 M4 x 30 3 6 3-W 4 + - 5 Ø 6.3 (0.25) 26.3 (1.04) 33 (1.3) Ø 44 (1.73) Terminals 1, 2: fieldbus connection Terminals 3 ... 6: sensor connection SITRANS TH400 dimensions in mm (inches) and connections Mounting on DIN rail SITRANS TH400, mounting of transmitter on DIN rail 50.5 (1.99) 33 (1.30) 59.6 (2.35) 14 (0.
© Siemens AG 2015 Temperature Measurement Transmitters for mounting in sensor head SITRANS TH400 fieldbus transmitter ■ Schematics Resistance thermometer Thermocouple Resistance 2 + Two-wire system 1) Internal cold junction compensation + Three-wire system Four-wire system Cold junction compensation with external Pt100 in three-wire system + Mean-value/differential or redundancy generation 2 x two-wire system 1) Three-wire system - 2 1 - Cold junction compensation with external Pt100 in tw
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TR200 two-wire system, universal ■ Overview ■ Application SITRANS TR200 transmitters can be used in all industrial sectors. Their compact design enables simple mounting on standard DIN rails on-site in protective boxes or in control cabinets.
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TR200 two-wire system, universal ■ Technical specifications Input Short-circuit monitoring can be switched on/off (default value: OFF) Measuring range parameterizable max. 0 ... 2200 (see table "Digital measuring errors") Min. measured span 5 ...
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TR200 two-wire system, universal Output 2 Certificates and approvals Output signal 4 ... 20 mA, 2-wire Explosion protection ATEX Auxiliary power 11 ...
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TR200 two-wire system, universal Resistance-based sensors Input Measuring range Min. measured span Digital accuracy Resistance 0 ... 390 5 0.05 Resistance 0 ... 2200 25 0.25 Measuring range Min. measured span Digital accuracy 2 Thermocouples Input °C/(°F) °C (°F) °C (°F) Type B 0 ... 1820 (32 ... 3308) 100 (180) 21) (3.6)1) Type C (W5) 0 ... 2300 (32 ... 4172) 100 (180) 2 (3.
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TR200 two-wire system, universal ■ Selection and Ordering data Article No. Temperature transmitter SITRANS TR200 2 For mounting on a standard DIN rail, two-wire system, 4 to 20 mA, programmable, with electrical isolation, with documentation on MiniDVD • Without explosion protection 7NG3032-0JN00 • With explosion protection to ATEX 7NG3032-1JN00 Further designs Order code Please add "-Z" to Article No.
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TR200 two-wire system, universal 2 8 5 6 7 SITRANS TR200 4 4..20mA 3 2 TEST 1 SIEMENS 22.5 ■ Schematics (0.89) ■ Dimensional drawings 1 2 TEST 3 4 4..20mA SIEMENS SITRANS TR200 99 (3.9) 5 6 7 8 Made in Croatia TC sens. with int./fixed CJC U sensor TC sensor with external 2W RTD CJC TC sensor with external 3W RTD CJC + 6 7 8 RTD or R 2W sensor 5 6 7 8 4..
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TR200 two-wire system, universal Resistance thermometer Thermocouple Resistance 2 5 6 7 8 5 6 7 8 5 R RTD Two-wire system 1) 5 6 7 5 5 6 7 Three-wire system 6 7 8 5 6 7 6 7 RTD 5 8 6 7 5 8 6 RTD Cold junction compensation with external Pt100 in three-wire system 7 8 5 R2 6 7 R1 RTD1 Generation of average value/difference 1) Generation of average value / difference with internal c
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TR300 two-wire system, universal, HART ■ Overview ■ Application SITRANS TR300 transmitters can be used in all industrial sectors. Their compact design enables simple mounting on standard DIN rails on-site in protective boxes or in control cabinets.
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TR300 two-wire system, universal, HART ■ Technical specifications Input Response time T63 250 ms for 1 sensor with opencircuit monitoring Open-circuit monitoring Always active (cannot be disabled) Short-circuit monitoring can be switched on/off (default value: OFF) Measuring range parameterizable max. 0 ...
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TR300 two-wire system, universal, HART Measuring range parameterizable max. -100 … 1100 mV Min. measured span 2 mV or 20 mV Overload capability of the input -1.5 ... +3.
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TR300 two-wire system, universal, HART Digital measuring errors Thermocouples Resistance thermometer Input Input 2 Measuring range Min. measured span Digital accuracy °C / (°F) °C (°F) °C (°F) Pt25 -200 ... +850 (-328 ... +1562) 10 (18) 0.3 (0.54) Pt50 -200 ... +850 (-328 ... +1562) 10 (18) 0.15 (0.27) Pt100 ... Pt200 -200 ... +850 (-328 ... +1562) 10 (18) 0.1 (0.18) Pt500 -200 ... +850 (-328 .
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TR300 two-wire system, universal, HART ■ Selection and Ordering data Accessories Article No.
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TR300 two-wire system, universal, HART 22.5 8 5 6 7 SITRANS TR300 4 4..20mA 3 2 TEST 1 SIEMENS 2 (0.89) ■ Dimensional drawings 99 (3.9) Made in Croatia TC sens. with int./fixed CJC U sensor TC sensor with external 2W RTD CJC TC sensor with external 3W RTD CJC + 6 7 8 RTD or R 2W sensor 5 6 7 8 4..
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TR300 two-wire system, universal, HART Resistance thermometer Thermocouple Resistance 2 5 6 7 8 5 6 7 8 5 R RTD Two-wire system 1) 5 6 7 5 5 6 7 6 7 8 5 6 7 6 7 RTD 5 8 6 7 5 8 6 RTD Cold junction compensation with external Pt100 in three-wire system 7 8 5 R2 6 7 8 TC2 - + TC1 - + R1 RTD1 Generation of average value/difference 1) 1) 8 TC - + Four-wire system RTD2 8 Cold jun
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TW four-wire system, universal, HART • Temperature-linear characteristic can be selected for all temperature sensors • Automatic correction of zero and span • Monitoring of sensor and cable for open-circuit and short- circuit • Sensor fault and/or limit can be output via an optional sensor fault/limit monitor • Hardware write protection for HART communication • Diagnostic functions • Slave pointer functions • SIL1 ■ Overview
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TW four-wire system, universal, HART ■ Integration ■ Technical specifications Input System configuration Selectable filters to suppress the line frequency SIMATIC S7-400 50 Hz, 60 Hz, also 10 Hz for special applications (line frequency filter is similar with measuring frequency) Resistance thermometer SIMATIC PDM ET 200M Control system UH Temperature Measuring range Parameterizable Measuring span min.
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TW four-wire system, universal, HART A-, mA sources Thermocouples 2 Measured variable Temperature Measured variable DC voltage Measuring range Parameterizable Measuring range Parameterizable Measuring span min. 50 °C (90 °F) x 1/scaling factor Characteristic curve Current-linear or customer- specific Measuring range limits Depend. on type of thermocouple element Thermocouple element Input range/min.
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TW four-wire system, universal, HART Certificates and approvals Auxiliary power Universal power supply unit 115/230 V AC/DC or 24 V AC/DC Tolerance range for power supply • With 115/230 V AC/DC PSU 80 ... 300 V DC; 90 ... 250 V AC • With 24 V AC/DC PSU 18 ... 80 V DC; 20.4 ... 55.2 V AC (in each case interruption-resistant up to 20 ms in the complete tolerance range) Tolerance range for mains frequency 47 ...
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TW four-wire system, universal, HART Digital error Thermocouples Resistance thermometer Measuring range Digital error1) °C / (°F) °C (°F) 0 ... +1820 (+32 ... +3308) 3 (5.4) Type C 0 ... +2300 (+32 ... +4172) 2 (3.6) Type D 0 ... +2300 (+32 ... +4172) 1 (1.8) Type E -200 ... +1000 (-328 ... +1832) 1 (1.8) Type J -210 ... +1200 (-346 ... +2192) 1 (1.8) Type K -200 ... +1372 (-328 ... +2501) 1 (1.
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TW four-wire system, universal, HART ■ Ordering examples Parameter: Example 2: SITRANS TW, transmitter in four-wire system • without explosion protection • 24 V AC/DC power supply • Voltage output • Sensor fault/limit monitor - Rating plate in English - Sensor NiCr/Ni, type K - Cold junction internal - Measuring range 0 ... 950 °C - Temperature-linear characteristic - Filter time 1 s - Output 0 ...
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TW four-wire system, universal, HART Selection and Ordering data Article No. SITRANS TW universal transmitter for rail mounting, in four-wire system (order instruction manual separately) 7 NG 3 2 4 2 - 77777 2 Selection and Ordering data 0 1 Power supply 115/230 V AC/DC 24 V AC/DC Cold junction terminal 7NG3092-8AV 7NG3092-8AW A U/I plug (-1.2 ... +10 V DC pr -12 ...
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TW four-wire system, universal, HART ■ List of parameterizable operating data (Order codes A 7 7 + B 7 7 ... E 7 7) Operating data acc. to default setting Order codes: A 7 7 ... E 7 7 Article No. with Order code: 7NG3242 - 7 7 7 7 7 -Z Y01 777 + 777 777 + + 777 777 + 2 Sensor Thermocouples Type Temperature range Connection B: Pt30 %Rh/Pt6 %Rh C:W5 %Re D:W3 %Re E:NiCr/CuNi J:Fe/CuNi (IEC) K:NiCr/Ni 0 ...
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TW four-wire system, universal, HART ■ List of parameterizable operating data (Order codes F 7 7 ... K 7 7) Operating data according to default setting Order codes: F 7 7 ... K 7 7 2 777 Article No. with Order code: 7NG3242 - 7 7 7 7 7 -Z Y01 + 777 + 777 + 777 + 777 Sensor Thermocouple elements Voltage measurement Type Temperature range B: Pt30 %Rh/ C:W5 %Re D:W3 %Re E:NiCr/CuNi J:Fe/CuNi (IEC) K:NiCr/Ni 0 ...
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TW four-wire system, universal, HART ■ Special operating data Order code Plain text required Options Y00 N= . Factor N for multiplication with the characteristic values of resistance thermometers Range of values: 0.10 to 10.00 1. Example: 3 x Pt500 parallel: N = 5/3 = 1.667; 2. Example: Ni120: N = 1.
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TW four-wire system, universal, HART ■ Schematics Sensor input connections 2 5 57' 5 57' 7& 7& P9 7& 7& 1* $9 3W 3W 7& 5 57' 5 57' 5 57' 8
© Siemens AG 2015 Temperature Measurement Transmitters for rail mounting SITRANS TW four-wire system, universal, HART Power supply connection Limit monitor 14 13 12 11 10 9 ~ ~ + UH 1 to 4 5, 6 7, 8 9 to 11 12 13, 14 Relay output HART/ 8 7 Sensor 6 5 HART + 4 3 2 1 2 - Signal input (see "sensor input connections" for possible types of connection) Analog output (U or I output parameterizable using plug-in jumpers) Connection with HART communication for local parameterization Output for sens
© Siemens AG 2015 Temperature Measurement Transmitters for field mounting SITRANS TF280 WirelessHART ■ Overview ■ Application The SITRANS TF280 is a WirelessHART field device for temperature measurement with a Pt100 sensor. This sensor can be installed directly on the field device, or connected at an offset with a cable connection. On the wireless communication side, the transmitter supports the WirelessHART standard.
© Siemens AG 2015 Temperature Measurement Transmitters for field mounting SITRANS TF280 WirelessHART ■ Technical specifications ES OS MS Industrial Ethernet SITRANS AW210 SIMATIC system SITRANS AW200 The SITRANS TF280 can be mechanically installed in two ways: • Direct at the measuring point with a M20x1.5 thread. A connection to other threads can be done via the adapter. • Remotely from the Pt100 sensor, which is connected to the transmitter via a cable.
© Siemens AG 2015 Temperature Measurement Transmitters for field mounting SITRANS TF280 WirelessHART 2 Displays and controls Selection and Ordering data Article No.
© Siemens AG 2015 Temperature Measurement Transmitters for field mounting SITRANS TF280 WirelessHART ■ Dimensional drawings 2 Antenna 112 (4.4) 130 (5.12) Ø 80 (3.15) 242 (9.5) 90 ° SW27 Pt100 154 (6.06) Ø 80 (3.15) Ø 8 (0.32) G½B 52 (2.05) 101 (3.98) 14 (0.55) 352 (13.9) SITRANS TF280 WirelessHART temperature transmitter with Pt100, dimensions in mm (inch). Please see the dimensional drawing of the mounting bracket on page 1/171.
© Siemens AG 2015 Temperature Measurement Transmitters for field mounting SITRANS TF280 WirelessHART 2 112 (4.4) 130 (5.12) Ø 80 (3.15) 242 (9.5) 90 ° Antenna 154 (6.06) 52 (2.05) Ø 80 (3.15) Cable gland for cable 6 ... 12 mm (0.24 ... 0.47 inch) 264 (10.4) SITRANS TF280 WirelessHART temperature transmitter, dimensions in mm (inch) Please see the dimensional drawing of the mounting bracket on page 1/171.
© Siemens AG 2015 Temperature Measurement Transmitter for field mounting/field indicator SITRANS TF - Transmitter, two-wire system and SITRANS TF - Field indicator for 4 to 20 mA ■ Overview ■ Function Configuration The communication capability over the HART protocol V 5.9 of the SITRANS TF with an integrated SITRANS TH300 permits parameterization using a PC or HART communicator (hand-held communicator). The SIMATIC PDM makes it easy.
© Siemens AG 2015 Temperature Measurement Transmitter for field mounting/field indicator SITRANS TF - Transmitter, two-wire system and SITRANS TF - Field indicator for 4 to 20 mA ■ Technical specifications Measuring range parameterizable max. 0 ... 2200 (see table "Digital measuring errors") Temperature Min. measured span 5 ... 25 (see Table "Digital measuring errors") • to IEC 60751 Pt25 … Pt1000 Characteristic curve • to JIS C 1604; a=0.
© Siemens AG 2015 Temperature Measurement Transmitter for field mounting/field indicator SITRANS TF - Transmitter, two-wire system and SITRANS TF - Field indicator for 4 to 20 mA Output Auxiliary power Output signal 4 ... 20 mA, 2-wire Communication with SITRANS TH300 acc. to HART Rev. 5.9 Without digital display 11 ... 35 V DC (30 V for Ex ib; 32 V for Ex ic and Ex nA) With digital display 13.1 ...
© Siemens AG 2015 Temperature Measurement Transmitter for field mounting/field indicator SITRANS TF - Transmitter, two-wire system and SITRANS TF - Field indicator for 4 to 20 mA Digital measuring errors Thermocouples Resistance thermometer Input Input 2 Measuring range Min. measured span Digital accuracy °C / (°F) °C) (°F) °C (°F) Pt25 -200 ... +850 (-328 ... +1562) 10 (18) 0.3 (0.54) Pt50 -200 ... +850 (-328 ... +1562) 10 (18) 0.15 (0.27) Pt100 ... Pt200 -200 ... +850 (-328 ...
© Siemens AG 2015 Temperature Measurement Transmitter for field mounting/field indicator SITRANS TF - Transmitter, two-wire system and SITRANS TF - Field indicator for 4 to 20 mA Selection and Ordering data Article No. Selection and Ordering data Temperature transmitter in field housing Two-wire system 4 ... 20 mA, with electrical isolation, with documentation on MiniDVD 7 NG 3 1 3 7 - 77777 Customer-specific programming Add "-Z" to Article No. and specify Order code(s) Click on the Article No.
© Siemens AG 2015 Temperature Measurement Transmitter for field mounting/field indicator SITRANS TF - Transmitter, two-wire system and SITRANS TF - Field indicator for 4 to 20 mA Selection and Ordering data Article No. Accessories 2 Modem for SITRANS TH100, TH200, TR200 and TF with TH200 incl.
© Siemens AG 2015 Temperature Measurement Transmitter for field mounting/field indicator SITRANS TF - Transmitter, two-wire system and SITRANS TF - Field indicator for 4 to 20 mA Selection and Ordering data Article No. Selection and Ordering data SITRANS TF field indicator for 4 ... 20 mA signals, with documentation on MiniDVD 7 NG 3 1 3 0 - 77777 Customer-specific programming Add "-Z" to Article No. and specify Order code(s) Click on the Article No.
© Siemens AG 2015 Temperature Measurement Transmitter for field mounting/field indicator SITRANS TF - Transmitter, two-wire system and SITRANS TF - Field indicator for 4 to 20 mA ■ Dimensional drawings 55 (2.17) 52 (2.05) 28 (1.10) 2 237 (9.33) a 3 36.5 (1.44) a: max. 164 (6.46) (M20x1.5) max. 189 (7.44) (½-14 NPT) 120 (4.72) 1 68 (2.68) 4 5 72 (2.83) 8 80 (3.15) 100* (3.94) 6 50 (1.97) 117 (4.61) 50* (1.97) b 20 (0.79) 138* (5.43) 80 (3.15) 2 144 (5.67) 13 (0.51) 15* (0.
© Siemens AG 2015 Temperature Measurement Transmitter for field mounting/field indicator SITRANS TF - Transmitter, two-wire system and SITRANS TF - Field indicator for 4 to 20 mA ■ Schematics 6 5 4 3 3 5 4 3 5 4 6 + - 6 5 4 2 5 + TC - 6 + - 6 5 4 Cold junction compensation Internal/fixed value Two-wire system 1) 3 3 5 4 3-W 3-W 4 3 R Two-wire system 1) 3 6 5 4 RTD 3 6 + - 3-W 4 6 + - 6 + - 6 5 4 5 RTD 3 3 4 3-W 3 3-W 3 Thermocouple Resistance 3-W
© Siemens AG 2015 Temperature Measurement Transmitters for field mounting SITRANS TF fieldbus transmitter ■ Overview ■ Application The SITRANS TF can be used everywhere where temperatures need to be measured under particularly harsh conditions. Which is why users from all industries have opted for this field device. 2 The rugged enclosure protects the electronics. The stainless steel model is almost completely resistant to sea water and other aggressive elements.
© Siemens AG 2015 Temperature Measurement Transmitters for field mounting SITRANS TF fieldbus transmitter System communication Bus terminator PROFIBUS PA Segment coupler SITRANS TF with TH400 PA • Type R -50 ... +1760 °C (-58 ... +3200 °F) • Type S -50 ... +1760 °C (-58 ... +3200 °F) • Type T -200 ... +400 °C (-328 ... +752 °F) to DIN 43710 • Type L -200 ... +900 °C (-328 ... +1652 °F) • Type U -200 ... +600 °C (-328 ...
© Siemens AG 2015 Temperature Measurement Transmitters for field mounting SITRANS TF fieldbus transmitter Conditions of use Communication Ambient conditions 2 Parameterization interface Permissible ambient temperature -40 ... +85 °C (-40 ... +185 °F) Permissible storage temperature -40 ... +85 °C (-40 ... +185 °F) - Protocol A&D profile, Version 3.
© Siemens AG 2015 Temperature Measurement Transmitters for field mounting SITRANS TF fieldbus transmitter Selection and Ordering data Article No. Selection and Ordering data Temperature transmitter in field enclosure with fieldbus communication and electrical isolation, with documentation on MiniDVD 7 NG 3 1 3 7 - 777 0 7 Customer-specific programming Add "-Z" to Article No. and specify Order code(s) Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
© Siemens AG 2015 Temperature Measurement Transmitters for field mounting SITRANS TF fieldbus transmitter Selection and Ordering data Article No. Accessories MiniDVD for temperature measuring instruments 2 A5E00364512 with documentation in German, English, French, Spanish, Italian and Portuguese, and parameterization software SIPROM T (included in delivery with SITRANS TF) SIMATIC PDM parameterization software also for SITRANS TF with TH400 PA See Sec.
© Siemens AG 2015 Temperature Measurement Transmitters for field mounting SITRANS TF fieldbus transmitter 55 (2.17) 28 (1.10) 80 (3.15) 100* (3.94) 6 2 2 3 36.5 (1.44) 120 (4.72) 1 a: max. 164 (6.46) (M20x1.5) max. 189 (7.44) (½-14 NPT) 68 (2.68) 4 72 (2.83) 5 237 (9.33) a Ø 80 (3.15) 50 (1.97) 52 (2.05) 50* (1.97) b 117 (4.61) 144 (5.67) 138* (5.43) 20 (0.79) ■ Dimensional drawings b: max. 25 (0.98) (M20x1.5) max. 50 (1.97) (½-14 NPT) 123 (4.
© Siemens AG 2015 Temperature Measurement Transmitters for field mounting SITRANS TF fieldbus transmitter ■ Schematics Thermocouple Resistance thermometer 2 Resistance + Internal cold junction compensation Two-wire system 1) + Three-wire system Three-wire system - Four-wire system Cold junction compensation with external Pt100 in three-wire system 2 1 + Mean-value/differential or redundancy generation 2 x two-wire system 1) - Cold junction compensation with external Pt100 in two-wire syste
© Siemens AG 2015 Temperature Measurement SITRANS TS500 Technical description ■ Overview 2 Temperature sensors of the SITRANS TS500 product family are used to measure temperatures in industrial equipment. ■ Benefits The modular design makes it possible to customize the temperature sensor for most applications, while still being able to use many standardized individual components.
© Siemens AG 2015 Temperature Measurement SITRANS TS500 Technical description ■ Design ■ Function A complete measuring point consists of a measuring insert which contains the basic sensors, the protective fitting and an optional transmitter. SITRANS TS500 7MC65xx 2 95 (3.74) The basic sensors are: • Resistance thermometers: Temperature measurement is based on the temperature dependency of the installed measuring resistor. • Thermocouples: Temperature measurement is based on the Seebeck effect.
© Siemens AG 2015 Temperature Measurement SITRANS TS500 Technical description ■ Configuration Components: Process connections Step down threaded well assemblies Flanges 2 The different properties of the flanges are as follows: • Standard series EN 1092, ASME 16.5,.. • Nominal pressure • Nominal diameter • Sealing face This information is stamped into the flange, as well as the material code and batch number for "3.1 Material".
© Siemens AG 2015 Temperature Measurement SITRANS TS500 Technical description Straight threaded well assemblies Tapered threaded well assemblies 2 A A T (1.75 std) T (1.75 std) NPT Process Connection NPT Process Connection OD 1 U U OD 1 Sensor OD Sensor OD 0.260 Bore 0.
© Siemens AG 2015 Temperature Measurement SITRANS TS500 Technical description Step down flanged well assemblies Straight flanged well assemblies 2 A A T (2.25 std) T (2.25 std) Weld Weld 3/4" U U Sensor OD 2 1/2" 0.260 Bore 0.
© Siemens AG 2015 Temperature Measurement SITRANS TS500 Technical description Tapered flanged well assemblies Step down socket well assemblies 2 A A T (1.75 std) T (2.25 std) P Weld OD 1 1/16" U U Sensor OD Sensor OD 0.260 Bore 5/8" 1/4" Dimensions in inch 2/80 Siemens FI 01 · 2015 US Edition 0.
© Siemens AG 2015 Temperature Measurement SITRANS TS500 Technical description Straight socket well assemblies Tapered socket well assemblies 2 A A T (1.75 std) T (1.75 std) P 1/2" NPT P OD1 OD1 U U Sensor OD Sensor OD 0.260 Bore 0.
© Siemens AG 2015 Temperature Measurement SITRANS TS500 Technical description General purpose sensors 2 1/2" x 1/2" NPT Double Ended Hex 316SS Fitting 1/2" x 1/2" NPT Adjustable Double Ended Hex 316SS Fitting Welded Spring Loaded Optional 316SS Adjustable Compression Fitting L L Dimensions in inch 2/82 Siemens FI 01 · 2015 US Edition L
© Siemens AG 2015 Temperature Measurement SITRANS TS500 Technical description Components: Connection head Connection head The connection head protects the connection department. The connection head features sufficient room for mounting a clamping base or transmitter. 2 Different connection heads are used depending on the application and preference. Components: Measuring insert Measuring inserts feature a large spring range.
© Siemens AG 2015 Temperature Measurement SITRANS TS500 Technical description 2 Measuring technology: Sensor elements Measuring technology: Measuring accuracy The diverse application spectrum for industrial temperature measuring technology requires different sensor technologies. Resistance thermometer Resistance thermometer Sensor elements made of other basic materials with different nominal resistances or different underlying standards are available on request.
© Siemens AG 2015 Temperature Measurement SITRANS TS500 Technical description Thermocouples The tolerance classes of the thermocouples correspond with IEC 584/EN 60584: Catalog versions Type Basic accuracy, Class 2 Increased accuracy, Class 1 K -40 °C ... +333 °C2.5 °C (-40 °F ... +631 °F 4.5 °F) -40 °C ... +375 °C1.5 °C (-40 °F ... +707 °F 2.7 °F) 333 °C ... 1000 °C±0.0075x|t[°C]| (631 °F ... 1832 °F ±0.0075x|t[°F]-32|) 375 °C ... 1000 °C ±0.004x|t[°C]| (707 °F ... 1832 °F±0.
© Siemens AG 2015 Temperature Measurement SITRANS TS500 Technical description Measuring technology: Mounting depth Measuring technology: Connection types Measuring insert Type 2 Temperature-sensitive length (TSL [mm (inch)] Non-bendable length [mm (inch)] Basic 50 (1.97) 30 (1.82) Increased vibration resistance 50 (1.97) 30 (1.82) Expanded measuring range 50 (1.97) 60 (2.36) Thermocouple 20 (0.79) 5 (0.
© Siemens AG 2015 Temperature Measurement SITRANS TS500 Technical description Temperature influence At the connection head TS5001) Without transmitter [°C (°F)] With transmitter [°C (°F)] Aluminum or stainless steel -40 ... +100 (-40 ... +212) -40 ... +85 (-40 ... +185) Plastic -40 ... +85 (-40 ... +185) -40 ... +85 (-40 ... +185) 1) 2 Notice manual at Ex-applications, please Influence of extension The illustration below assists you in selecting the right T length for the neck tube.
© Siemens AG 2015 Temperature Measurement SITRANS TS500 Technical description Thermowell calculation Properly applied load diagrams will provide a sufficient degree of safety for the most common thermowell configurations. 2 However, there are cases in which operating conditions deviate too greatly from standard parameters. In this case, a customized thermowell calculation may be required.
© Siemens AG 2015 Temperature Measurement SITRANS TS500 Technical description Vibration resistance of measuring insert, cable sensor Similar to the thermowell, inner (Karman vortices) and outer (plant) vibrations also affect the measuring insert. For this reason, a special assembly of measurement elements is required. Other than a few exceptions for cable and compact thermometers, Siemens only produces sensors based on a mineral-insulated cable.
© Siemens AG 2015 Temperature Measurement SITRANS TS500 Selection and Ordering data 2 Selection and Ordering data Article No. SITRANS TS500 Threaded sensor assembly (no thermowell) 7MC650 Ord. Code 7 - 7 7 7 7 7 - 00 7 7 7 7 7 7 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Sheath Material 316L Stainless Steel 310 Stainless Steel Alloy 600 Article No.
© Siemens AG 2015 Temperature Measurement SITRANS TS500 Selection and Ordering data Selection and Ordering data Order Code Options Add "-Z" to Article No. and add options, separate extensions with "+". Explosion protection ATEX Intrinsic safety "ia", "ic" E01 ATEX Flameproof enclosure "d" E02 ATEX Non sparking "n" E03 cFMus intrinsic safety E11 cFMus explosion proof E13 2 Transmitter mounted in head Measuring range to be set must be specified with plain text data "Y01".
© Siemens AG 2015 Temperature Measurement SITRANS TS500 Selection and Ordering data 2 Selection and Ordering data Article No. SITRANS TS500 Barstock Thermowell Assembly 7MC652 Ord. Code Selection and Ordering data Article No. 7MC652 7 - 7 7 7 7 7 - 07 7 7 7 7 7 7 SITRANS TS500 Barstock Thermowell Assembly Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
© Siemens AG 2015 Temperature Measurement SITRANS TS500 Selection and Ordering data Selection and Ordering data Order Code Options Order Code Full Penetration Welding for Flanged Process Connections Add "-Z" to Article No. and add options, separate extensions with "+". Transmitter mounted in head Measuring range to be set must be specified with plain text data "Y01".
© Siemens AG 2015 Temperature Measurement SITRANS TS500 Schematics ■ Schematics Thermocouples Resistance thermometer 1 thermocouple 2 thermocouples + + + - - - Double Pt100 measuring inserts (for 6 mm OD only) are designed as a three-wire system. 3-conductor connection 2-conductor connection 1 x Pt100 4-conductor connection 2 SITRANS TSinsert measuring inserts are designed as a four-wire system for single Pt100 if not mentioned differently.
© Siemens AG 2015 Temperature Measurement SITRANS TS500 Schematics Coun International/ try Germany North America UK/ Czech Republic Stan- Not intrinsically dard safe1) Extension lead2) BS 1843 Jacket + - Jacket + - Jacket + - N PN PN WH OG OG RD OG OG BU K GN GN WH YE YE RD RD BR BU J BK BK WH BK WH RD BK YE BU T BR BR WH BU BU RD BU WH BU E VT VT WH VT VT RD BR BR BU R+S OG OG WH BK RD GN WH BU B GY GY WH GY RD - - - GY 1) W
© Siemens AG 2015 Temperature Measurement SITRANS TS500 Temperature transmitters for mounting in the connection head ■ Overview ■ Selection and Ordering Data Detailed information on the transmitters can be found for the respective products under "Transmitters for temperature“. 2 Transmitter to be fitted Order code To order the sensor with a built-in temperature transmitter, add "-Z" to the Article No.