User's Manual

Siemens PLT 130
.
1994
4/19
Connection of remote bus cables
It may be necessary when using remote bus cables to connect
sections together . The type of connection differs depending on
thetypeofcable:
Standard remote bus cable V45466-D21-B35 and
in-house
cable
V45466-D17-B135
These cables can be connected by splicing or by using RF
plugs.
Remote bus cables V45466-D21-B65 and
-B55
Only splicing is possible for connecting these cables. To pro-
vide additional protection against mechanical damage, the con-
nection should be enclosed in a metal sleeve. The cable ar-
mouring can be electrically connected using a copper cable
(e. g. as additional overvoltage protection) and secured to pre-
vent tens ion. The s leeve is f illed with sealing compound follow-
ing as s embly.
All parts required for the connection, both for the cable connec-
tion itself and also the sleeve and sealing compound, can be
obtained as a parts kit for splicing coaxial cables. Instructions
are included with the kit.
Ordering data
Order No.
For remote bus cables V45466-D21-B35 and
V45466-D17-B135:
Parts kit for splicing coaxial cables
(1 kit is required per connection point)
S45056-M125-A1
Al-foil, 50 mm wide, 250 mm long;
package with 100 foils
(2 off required per connection point)
C45197-A1 14-C330
Cable plug 4.6-16
(2 plugs requir ed per connection point)
SPN:684732-00
Coupling SPN:683500
Heat-shrinkable sleeve, length approx. 250 mm 5GF2603
Al foil, 50 mm wide, 250 mm long;
package with 100 foils
(2 off required per connection point)
C45197-A1 14-C330
For remote bus cables V45466-D21-B65 and
V45466-D21-B55:
Parts kit for splicing coaxial cables
(1 kit is required per connection point)
S45054-A271-A1
Al foil, 50 mm wide, 250 mm long,
package with 100 foils
(2 off r equired per connection point)
C45197-A1 14-C330
Created with "Chameleon CMYK PDF Creator" for Wolfgang Strozyk at Siemens AG
This catalog is out of date, see note on page 2