Security Camera User Manual

Configuration with the CCIC1410 Homepage
78
Siemens Building Technologies
Fire Safety & Security Products 05.2009
z Media Type:
Snapshot:
Select to send snapshots when a trigger is activated.
Î Source:
Select whether to use snapshots from stream 1 or stream 2.
Î Send pre-event images:
The network camera has a buffer area; it temporarily holds data up to a certain
limit. Specify how many images are to be captured before a trigger is activated.
Up to seven images can be generated.
Î Send post-event images:
Specify how many images are to be captured after a trigger is activated. Up to
seven images can be generated. For example, if both the Send pre-event
images and Send post-event images are set to seven, a total of 15 images are
generated after a trigger is activated.
Video clip:
Select to send video clips when a trigger is activated.
Î Source:
Select whether to record video clips from stream 1 or stream 2.
Î Pre-event recording:
The network camera has a buffer area; it temporarily holds data up to a certain
limit. Specify for how many seconds video clips are to be recorded before a
trigger is activated. Up to nine seconds can be set.
Î Maximum duration:
Specify the maximum recording duration in seconds. Up to ten seconds can be
set. For example, if the pre-event recording is set to five seconds and the
maximum duration is set to ten seconds, the network camera continues to
record for another four seconds after a trigger is activated.