Mounting Instructions

Building Technologies
Fire Safety & Security Products
Component License key
This component is only allowed to be operated if it is installed in a fire control panel in the Desigo or
CerberusPro series. When properly installed by a trained specialist, the component does not negatively
influence the EMC characteristics of the fire control panel.
The documentation for the technical details of the component can be found in the following instruction manuals:
Desigo Cerberus PRO
Planning A6V10315013 A6V10333396
Mounting / Installation / Product Data A6V10315015 A6V10333409
Electrical installations
WARNING
Electrical voltage
Electric shock
Work on electrical installations may only be carried out by certified electricians or by instructed
persons working under the guidance and supervision of a certified electrician, in accordance with the
electrotechnical regulations.
Before a station is opened, it must be put out of operation, and the mains supply must be interrupted.
The device is current-free after it has been disconnected from the mains and the batteries.
Wherever possible disconnect products from the power supply when carrying out commissioning,
maintenance or repair work on them.
Lock volt-free areas to prevent them being switched back on again by mistake.
Label the connection terminals with external voltage using a 'DANGER External voltage' sign.
Route mains connections to products separately and fuse them with their own, clearly marked fuse.
Fit an easily accessible disconnecting device in accordance with IEC 60950-1 outside the installation.
Insert license key
The license key is inserted in the retainer provided on the rear of the operating unit.
1
2
Inserting the license key into the operating unit
1 Support for license key
2 License key
Installation position: The broader flat side is at the top on the clamp.
Raise clamp of retainer (1) slightly and push the license key (2) underneath the clamp.