Data and design subject to change without notice. / Supply subject to availability. © 2008 Copyright by Siemens Building Technologies We reserve all rights in this document and in the subject thereof.
Contents 1 1.1 1.2 1.3 1.4 Safety .......................................................................................................5 Target group..............................................................................................5 General safety precautions .......................................................................5 Meaning of the written warning notices ....................................................5 Meaning of the hazard symbols .........................................
Safety 1 Safety 1.1 Target group The instructions in this document are designed only for the following target group. 1.2 Target group Qualification Activity Condition of the product Installer Technical training for building or electrical installations. Assembles/installs the product, individual components of the product or replacement parts. Components of the product are not yet assembled/installed or need to be replaced.
EU Directives 2 EU Directives The product complies with the requirements of the following EU directives. The EU declaration of conformity is available from: Siemens Building Technologies Fire & Security Products GmbH & Co.
Technical data 3 Technical data 3.1 Specifications Mechanical Length 230 mm Width 190 mm Height 300 mm Weight Empty: 2 kg Full: 7 kg Material Wall bracket: Stainless steel Pump unit case: Polycarbonate Washer container: H.D.P.
Technical data 3.2 Mechanical dimensions Fig. 1 1 3.3 Dimensions 10 m maximum Key to parts Fig. 2 Key to parts 1 Camera housing 2 Nozzle assembly 3 Pump inlet pipe 4 Pump outlet pipe 5 Pump unit 6 Supply cable 8 Siemens Building Technologies Fire Safety & Security Products 09.
Scope of delivery 4 Scope of delivery z Pump unit with lid z 5 litre container z Support bracket z Retaining strap z Container cap and inlet pipe assembly z 5 mm bore tubing (600 mm long) z 3 mm bore tubing (10 metres long) z Small parts kit z Installation Guide Small parts kit z Washer nozzle bracket z Nozzle assembly z Black threaded outlet adaptor z M4×10 Stainless steel screws (2 x) z M4 Fibre washers (2 x) 5 Description of equipment The washer unit has been designed to operate with any Siemens cam
Installation and operation 6 Installation and operation 6.1 Installation 1. A readily accessible disconnect device shall be incorporated in the building installation wiring. In compliance with IEC60335 this device should ensure allpole disconnection and contact separation, providing full disconnection under overvoltage category III. 2. As part of the building installation protect the unit via a fuse or circuit breaker rated at 3 A for CAHL4010-WU 230 V AC or 5 A for CAHL4011-WU 24 V AC. 3.
Installation and operation NOTE Ensure that the nozzle is positioned so that the hole is facing the housing window. 14. Lower the pipe (tying may be required to provide support), cut to length if required and push the lower end into the black (outlet) connector on the pump unit. Ensure that the pipe is inserted until it “bottoms” in the connector (15 mm nom). Do not remove the central “loose” insert.
Installation and operation 6.2 Operation 1. Regularly check the level of cleaning fluid in the washer container. Risk of damage to the pump unit due to its running dry IMPORTANT The pump unit may be damaged due to lack of water in the container. z Regularly refill the washer container with cleaning fluid. 2. The container can be fully removed if required by carefully unbuckling the retaining strap. After filling this strap should be re-fastened. 3.
Maintenance and service 7 Maintenance and service The following maintenance guidelines should be observed. 1 month after installation and every 6 months thereafter Check the tightness and security of all external fastenings 6 monthly checks Check electrical cables and pipes for signs of wear. Replace where necessary. Check that the cables are not fouling on any obstruction. NOTE This installation guide cannot cover all conceivable cases of installation, operation or maintenance.
Disposal 9 Disposal All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities. This crossed-out wheeled bin symbol on the product means the product is covered by the European Directive 2002/96/EC. The correct disposal and separate collection of your old appliance will help prevent potential negative consequences for the environment and human health.
Issued by Siemens Building Technologies Fire & Security Products GmbH & Co. oHG D-76181 Karlsruhe www.buildingtechnologies.siemens.com Document no. A6V10087770 Edition 24.09.2008 © 2008 Copyright by Siemens Building Technologies Data and design subject to change without notice. Supply subject to availability.