Specifications

SiPass Entro
Door Modules
2-7© Siemens Switzerland Ltd 2011
2
Type Order No.
DC01
Door controller for use without reader
The DC01 is designed to monitor and control one door in a SiPass Entro
system. When it is connected to a door it continuously reports the sta-
tus of that door (open or closed) to the system‚ which increases the lev-
el of security in the building. The DC01 cannot be connected to a read-
er. However‚ it can be used to unlock the door and thereby grant access
to the public‚ for example‚ during certain times of the day or week‚
based on timer settings in the SiPass Entro system.
Interface To segment controller: RS485 sys-
tem com bus
Operating voltage 8 to 40 VDC or 8 to 30 VAC
Power consumption Power save 12V DC: 0.24 W
Full on 12V DC: 0.72 W
Power save 24V DC: 0.48 W
Full on 24V DC: 1.44 W
Inputs Exit button request with delay. Door
contact for indicating closed/open
door. Tamper switch for internal
control.
Outputs Voltage-free relay contact‚ max. 2 A‚
30 V
Tamper switch Yes
Operating temperature -35 to +50 °C
Environment Indoor use only
Housing Plastic box
Colour White
Dimensions (W x H x D) 120 x 80 x 40 mm
Weight 0.16 kg
Approval CE
S24246-C8500-A1