Specifications

SiPass Entro
Door Modules
2-8 © Siemens Switzerland Ltd 2011
Type Order No.
DC12
Door controller for use with reader(s)
The DC12 is designed to monitor and control one door in a SiPass Entro
or SiPass integrated system. When BC-Link is used‚ a single DC12 can
support two readers and thereby control both entries and exits to a
restricted area (anti-passback).
The DC12 includes an integrated status display window to simplify
installation and service. It is compatible both with SiPass readers and
with most third-party readers that support Wiegand and Clock&Data
standards.
Interface To reader: BC-Link‚ Clock&Data
(track 2) or Wiegand (26 bit‚ 32 bit‚
8 bit burst)
To controller: RS485 system com
bus
Operating voltage 8 to 40 VDC‚ 8 to 30 VAC
Power consumption Without reader
Power save 12V DC: 0.59 W
Full on 12V DC: 0.76 W
Power save 24V DC: 0.63 W
Full on 24V DC: 0.79 W
Inputs Exit button request with delay. Door
contact for indicating closed/open
door
Outputs Voltage-free relay contact‚ max. 2 A‚
30 V.
Tamper switch Integrated
Operating temperature -35 to +50 °C
Environment Indoor use only
Housing Wall-mounted composite housing
Colour White
Dimensions (W x H x D) 250 x 128 x 54 mm
Weight 0.5 kg
Approval CE
S24246-C8502-A1