System Board D2559 for TX150 S6 Technical Manual Edition November 2007
Comments… Suggestions… Corrections… The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by e-mail to manuals@fujtsu-siemens.com.
Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2 Important notes . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.1 Notes on safety . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.2 CE Certificate . . . . . . . . . . . . . . . . . . . . . . . . . . 10 2.3 Environmental Protection . . . . . . . . . . . . . . . . . . . 11 3 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3.1 Overview . . . . . . . . . . . . . . . . . . . . .
1 Introduction This technical manual describes the system board D2559, which is equipped with one Intel® processor. Further information about drivers is provided in the readme files on the hard disk, on the supplied “ServerStart“ or “Update“ CDs. You will find further information in the BIOS description.
2 Important notes In this chapter you will find essential information regarding safety when working with your server. V CAUTION! With the system board installed you must open the system to access the system board. How to access the system board of your system is described in the appropriate service supplement. When handling the system board, refer to the specific notes on safety in the operating manual and/or service supplement for the respective server. 2.
Notes on safety V Important notes ● Components can become very hot during operation. Ensure you do not touch components when making extensions to the system board. There is a danger of burns!. ● Transmission lines to peripheral devices must be adequately shielded. ● To the LAN wiring the requirements apply in accordance with the standards EN 50173 and EN 50174-1/2.
Important notes Notes on safety Modules with electrostatic-sensitive components Systems and components that might be damaged by electrostatic discharge (ESD) are marked with the following label: Figure 1: ESD label When you handle components fitted with ESDs, you must observe the following points under all circumstances: ● You must always discharge yourself of static charges (e.g. by touching a grounded object) before working. ● The equipment and tools you use must be free of static charges.
CE Certificate Important notes Notes about boards ● During installation/deinstallation of the system board, observe the specific instructions described in the service manual for the server. ● Remove the plug from the mains outlet so that system and system board are totally disconnected from the mains voltage. ● To prevent damage to the system board, the components and conductors on it, please take great care when you insert or remove boards.
Important notes 2.3 Environmental Protection Environmental Protection Environmentally friendly product design and development This product has been designed in accordance with standards for ”environmentally friendly product design and development“. This means that the designers have taken into account important criteria such as durability, selection of materials and coding, emissions, packaging, the ease with which the product can be dismantled and the extent to which it can be recycled.
Environmental Protection Important notes Returning, recycling and disposal The device may not be disposed of with household rubbish. This appliance is labelled in accordance with European Directive 2002/96/EC concerning used electrical and electronic appliances (waste electrical and electronic equipment - WEEE). The guideline determines the framework for the return and recycling of used appliances as applicable throughout the EU.
3 Features 3.
Overview Features Internal connectors – dual USB 2.0 – SATA (1-4) multilane – 2x SATA – floppy disk – SAS/SATA/HD Activity LED – front panel – CPU fan 4 pins – system fan 4 pins – 4x system fans 5 pins – PC98 – power (12V, -12V, 5V, 3.3V and 5V auxiliary) – 12V (CPU) power – intrusion detection – SMB PCI slots – 3 x PCI (32 Bit / 33 MHz) – 2 x PCI Express x8 – 1 x PCI Express x4 BIOS features – – – – – – – – Phoenix System BIOS V 6.00 SMBIOS 2.34 (DMI) MultiProcessor specification 1.
Features Overview Environmental protection Battery in holder for recycling Form factor, slot compatibility list – ATX dimension: 305 mm x 244 mm – ACPI 1.0b, OnNow, PCI 2.3, PCI Express 1.0a, WfM 2.0, SHDG 3.0, MPS 1.4, IPMI 2.0, PCI SHPC 1.0, USB2.0 CSS (Customer Self Service) This system board supports the CSS functionality. You will find a description of CSS functionality in the operating manual of your server.
Main memory 3.2 Features Main memory The system board supports up to 16 Gbyte ECC main memory. 4 slots (2 memory banks with 2 modules) are available for the main memory. Each memory bank can be populated with 256 Mbyte, 512 Mbyte, 1 Gbyte, 2 Gbyte or 4 Gbyte unbuffered DDR2 memory modules. ECC memory modules are supported only. I You will find the descriptions how to install memory modules in the Options Guide of your server.
Features Main memory Following table shows examples for configurations Mode DIMM 1A (black) DIMM 2A (blue) DIMM 1B (black) DIMM 2B (blue) singlechannel populated - - - single/dualchannel 1 populated populated populated - populated - populated - populated populated populated populated dual-channel 1 The dual-channel mode is only activated, if the size of the memory module in socket DIMM 2A is equal to the summary of the sizes of the memory modules in the sockets DIMM 1A and DIMM 1B.
PCI bus 3.
Features PCI bus PCI and PCI-X buses use four lines named INTA to INTD, typically connected to all devices on the bus in order to periodically balance interrupt load. An interrupt signal may thereby be used simultaneously by multiple devices (interrupt sharing). PCI Express devices send their interrupts through messages. This avoids restrictions in wiring.
Screen resolution 3.4 Features Screen resolution Depending on the operating system used the screen resolutions in the following table refer to the graphic controller on the system board. The MATROX G200 graphic controller is integrated in the iRMC (integrated Remote Management Controller). Screen resolution Max. color depth Max.
Features Temperature / system monitoring Fan monitoring The CPU, power supply unit and system fans are monitored. Fans that are no longer available, blocked or sticky fans are detected. Fan control The fans are regulated according to temperature. Sensor monitoring The removal of, or a fault in, a temperature sensor is detected. Should this happen all fans monitored by this sensor run at maximum speed, to achieve the greatest possible protection of the hardware.
LEDs 3.6 Features LEDs C E D B A Super I/O Slot 6 F Slot 5 F PCIe x8 PCIe x8 Slot 4 RAID key E E MCH E LAN DIMM1B DIMM2B DIMM1A DIMM2A CPU PCIe x4 Battery CSS button F Slot 3 PCI 32 Bit / 33 MHz F Slot 2 F Slot 1 F PCI 32 Bit / 33 MHz PCI 32 Bit / 33 MHz E iRMC G E Figure 4: LEDs LED s A, B and C are visible from outside on the rear of the server. All the other LEDs are only visible, if the cover of the server has been opened.
Features LEDs The LEDs have the following meaning: LED Indicator Meaning A - GEL (Global Error LED) amber indicates a prefailure B - CSS (Customer Self Service) yellow indicates a prefailure yellow flashing indicates a failure amber flashing indicates a failure.
Interfaces and connectors 3.
Features Interfaces and connectors 10 = USB 24 = PCI slots 11 = power supply ATX 12V 25 = RAID key 12 = CSS button 26 = serial interface 2 13 = Mini SAS 27 = system fan 1 14 = SATA 5 28 = external ports RAID key The SATA SW RAID 5 functionality will be activated by installing a license key (RAID key). 3.7.
Interfaces and connectors Features LAN connectors On this system board you will find two LAN controllers: a Gigabit LAN controller (Broadcom BCM5755T) and a service LAN controller. The Gigabit LAN controller BCM5755T supports the transfer rates of 10 Mbit/s, 100 Mbit/s and 1 Gbit/s. The Service LAN controller supports the transfer rates of 10 Mbit/s and 100 Mbit/s. The LAN controllers support WOL function through Magic Packet™. It is also possible to boot a device without its own boot hard disk via LAN.
Features Interfaces and connectors 2 1 Figure 8: LAN connector service LAN controller 1 LAN transfer rate green off transfer rate 10 Mbit/s green on transfer rate 100 Mbit/s green on LAN connection off no LAN connection flashing LAN transfer 2 LAN link/activity D2559 (TX150 S6) Technical Manual 27
Settings with jumpers 3.8 Features Settings with jumpers default RCVR PWD SKIP Figure 9: Jumpers Recovering system BIOS - jumper RCVR RCVR enables recovery of the old system BIOS after an attempt to update has failed. To restore the old system BIOS you need a Flash BIOS Diskette (please call our customer service centre). being set The system boots from the “Flash BIOS floppy disk“ from drive A and reprograms the system BIOS on the board.
4 Replacing the lithium battery In order to save the system information permanently, a lithium battery is installed to provide the CMOS-memory with a current. When the charge is too low or the battery is empty, a corresponding error message is provided. The lithium battery must then be replaced. V The lithium battery must be replaced with an identical battery or a battery type recommended by the manufacturer (CR2032). Do not throw lithium batteries into the trash can.
Abbreviations The technical terms and abbreviations given below represent only a selection of the full list of common technical terms and abbreviations. Not all technical terms and abbreviations listed here are valid for the described system board.
Abbreviations DIP Dual In-line Package DMI Desktop Management Interface DRAM Dynamic Random Access Memory ECC Error Correction Code EEPROM Electrical Erasable Programmable Read Only Memory EPROM Erasable Programmable Read Only Memory EMRL Embedded RAID Logic EVRD Enterprise VRD HPC Hot-plug Controller ICE In Circuit Emulation IDE Integrated (intelligent) Drive Electronics IME Integrated Mirror Enhanced IOOP Intelligent Organization Of PCI IPMB Intelligent Platform Management Bus 32 Technical Manual D2559
Abbreviations IPMI Intelligent Platform Management Interface iRMC integrated Remote Management Controller LAN Local Area Network LED Light Emitting Diode MPS Multi Processor Specification NMI Non Maskable Interrupt OEM Original Equipment Manufacturer OHCI Open Host Controller Interface OS Operating System PCI Peripheral Components Interconnect PDA Prefailure Detection and Analyzing PIO Programmed Input Output PLD Programmable Logic Device PS(U) Power Supply (Unit) D2559 (TX150 S6) Technical Manual 33
Abbreviations PWM Puls Wide Modulation PXE Preboot eXecution Environment RAID Redundant Array of Inexpensive Disks RSB Remote Service Board RST ReSeT RTC Real Time Clock SAS Serial Attached SCSI SATA Serial ATA SCSI Small Computer Systems Interface SDDC Single Device Data Correction SDRAM Synchronous Dynamic Random Access Memory SHDG Server Hardware Design Guide SMB System Management Bus SMM Server Management Mode 34 Technical Manual D2559 (TX150 S6)
Abbreviations SMP Symmetrically Multi Processing UHCI Unified Host Controller Interface USB Universal Serial Bus VGA Video Graphics Adapter VRD Voltage Regulator Down VRM Voltage Regulator Module WfM Wired for Management WOL Wake up On LAN D2559 (TX150 S6) Technical Manual 35