Data Sheet for Product
Siemens
Building Technologies Division
Data Sheet 7317
usa.Siemens.com/desigo-fire-safety
Desigo® Fire Safety Modular
Switch-Control Module | LED-Control Module
| Fan-Control Module
Models SCM-8, LCM-8 and FCM-6
Architect & Engineer Specifications
Eight (8) programmable switches
(Model SCM-8)
Six (6) sets of the push-button,
programmable fan-control switches
(Model FCM-6)
Multi-color light-emitting diodes (LEDs)
for clear indication of system status
Manual `ON’ | `OFF’ |
`Automatic’ positions
LED indication of fan status
(`ON’ / `OFF’ / `Trouble’)
Protected space provided for labeling
LED indication of fan status
(`ON’ / `OFF’ / `Trouble’)
Programmable LED annunciation
Remote mounting in Model
REMBOX2 or REMBOX4 enclosures
Supervised positive system feedback
Protected label provided
Modular
Activation-stagger timer
UL864 & CAN / ULC-S576 Listed; FM,
CSFM & NYCFD Approved
Product Overview
Model
SCM-8
Model SCM
-8 is a Siemens Desigo Fire Saf
ety Modular system option module that
provides manual control of the emergency voice
-evacuation or manual fire-system
control. Each Model SCM
-8 module provides eight (8) momentary push-button
switches and 16 light
-emitting diodes (LEDs) to indicate their status.
Each switch is assigned two (2) LEDs and a label to indicate the switch's
programmed usage. The label slides behind a clear, protective membrane. One of
the LEDs assigned to each switch is a dual
-
color LED used to indicate what type of
signal is active. This LED may also be lighted steady or flashing to further indicate
system status.
For example, zones active to the evacuation audio channel will have the LED lighted
R
ED and steady; zones active to the `Alert’ audio channel will have the LED ligh
ted
R
ED and flashing; zones selected for paging will have the LED lighted GREEN
and
flashing until the microphone key is pressed.
When the zone
-transfer confirmation message is received by the De
sigo Fire Safety
Modular system
-command console, the LED will change to steady GREEN
, indicating
that it is clear to page. Telephone zones with an incoming call in progress will have
an LED flashing
GREEN until selected at the command console ─
at which time the
LED will change to steady
GREEN, etc. This process a
llows the operator easy, clear
access to the overall system condition at all times. The second LED is
AMBER
, and is
used to indicate a fault condition.
Each Model SCM
-
8 switch module is fully programmable, and may be used to
control speaker circuits and a
wide range of general system functions such as: `
All
Call’,
`
All Evac’, `Warden's Page’, `Speaker’, etc. Any number of circuits may be
grouped and controlled by a single switch. Switch usage and zone groupings are
assigned using the
Zeus-D system programming software.
Each Model SCM
-8 module is mounted on a hinged panel as a part of
the Desigo Fire Safety Modular system command console enclosure.
Model FCM-6
Fan-Control Module
Model LCM-8
LED-Control Module
Model SCM-8
Switch-Control Module