Technical data

List of Parameters
Parameters
1-447
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
Description: Setting parameter for the run-time group in which instance LVM 0 of the double-sided limiter is to be called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance LVM 0 within the run-time group set in p20273.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantity X of instance LVM 1 of the double-sided limiter.
Description: Setting parameter for the interval average M of instance LVM 1 of the double-sided limiter.
Description: Setting parameter for the interval limit L of instance LVM 1 of the double-sided limiter.
p20273 LVM 0 run-time group / LVM 0 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
5 9999 9999
p20274 LVM 0 run sequence / LVM 0 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
0 7999 720
p20275 CI: LVM 1 input X / LVM 1 input X
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - 0
p20276 LVM 1 interval average value M / LVM 1 avg value M
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
-340.28235E36 340.28235E36 0.0000
p20277 LVM 1 interval limit L / LVM 1 limit L
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
-340.28235E36 340.28235E36 0.0000