User Manual
Parameters
List of parameters
1-200
© Siemens AG 2009 - 2013 All Rights Reserved
SINAMICS G120 CU240B/E-2 Control Units List Manual (LH11), 01/2013
Description: Displays the current controller status word.
Description: Sets the time constant for the speed setpoint filter 1 (PT1).
Description: Display and connector output of the speed setpoint after setpoint limiting for the P component of the speed control-
ler.
For U/f operation, the value that is displayed is of no relevance.
Dependency: Refer to: r1439
Note: In the standard state (the reference model is de-activated), r1438 = r1439.
Description: Displays the speed setpoint for the I component of the speed controller (output of the reference model after the set-
point limiting).
Dependency: Refer to: r1438
Note: In the standard state (the reference model is de-activated), r1438 = r1439.
r1408.0...14 CO/BO: Status word current controller / ZSW I_ctrl
Access level: 4 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 2530
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Current controller act Active Not active -
01 Id control I component limiting Active Not active 6714
03 Voltage limiting Active Not active 6714
10 Speed adaptation limiting Active Not active -
12 Motor stalled Yes No -
13 Separately excited synchronous motor is
excited
Yes No -
14 Current model FEM: magnetizing excitation
current limited to 0
Yes No -
p1416[0...n] Speed setpoint filter 1 time constant / n_set_filt 1 T
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: 1700, 6030
Min Max Factory setting
0.00 [ms] 5000.00 [ms] 0.00 [ms]
r1438 CO: Speed controller speed setpoint / n_ctrl n_set
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2000 Dyn. index: -
Units group: 3_1 Unit selection: p0505 Func. diagram: 1550, 1590, 1700,
5030, 5040, 5042, 5210, 5300, 5620,
6031, 6040
Min Max Factory setting
- [rpm] - [rpm] - [rpm]
r1439 Speed setpoint I component / n_set I_comp
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2000 Dyn. index: -
Units group: 3_1 Unit selection: p0505 Func. diagram: 5030, 5040, 6031
Min Max Factory setting
- [rpm] - [rpm] - [rpm]