SINAMICS G120 CU240B/E-2 Control Units List Manual (LH11), 01/2013
Dependency: IEC drives (p0100 = 0): unit kg m^2
NEMA drives (p0100 = 1): unit lb ft^2
Refer to: p0341, p0342, p1959
Refer to: F07984
Description: Displays the vibration frequencies determined by the vibration test.
Index: [0] = Frequency low
[1] = Frequency high
Dependency: Refer to: p1959
Refer to: F07985
Description: Sets the maximum flux setpoint to measure the saturation characteristic.
Description: Sets the pole position identification technique.
p1980 = 1: The current magnitude is set using P0329.
p1980 = 4, 6: The current magnitude of the first measurement section is set using p0325, the second using p0329.
p1980 = 10: The rated motor current is impressed to align.
The current magnitudes are limited to the rated power unit values.
Value: 1: Voltage pulsing 1st harmonics
4: Voltage pulsing 2-stage
6: Voltage pulsing 2-stage inverse
10: DC current injection
Dependency: When commissioning a catalog motor, the technique is automatically selected depending on the motor type being
used.
Refer to: p0325, p0329, p1780
Refer to: F07969
Note: Voltage pulse technique (p1980 = 1, 4) cannot be applied to operation with sine-wave output filters (p0230).
r1970[0...1] Speed_ctrl_opt vibration test vibration frequency determined / n_opt f_vib det
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [Hz] - [Hz] - [Hz]
p1974 Speed_ctrl_opt saturation characteristic maximum rotor flux / n_opt rotflux_max
Access level: 4 Calculated: p0340 = 1 Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
104 [%] 120 [%] 120 [%]
p1980[0...n] PolID technique / PolID technique
Access level: 3 Calculated: p0340 = 1,3 Data type: Integer16
Can be changed: U, T Scaling: - Dyn. index: MDS
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
1 10 4