User Manual
Parameters
List of parameters
1-266
© Siemens AG 2009 - 2013 All Rights Reserved
SINAMICS G120 CU240B/E-2 Control Units List Manual (LH11), 01/2013
Notice: A maximum of 4 indices of the "trace" function can be used.
Description: Display for the maximum interconnected PZD in the receive/send direction
Index 0: receive (r2050, r2060)
Index 1: send (p2051, p2061)
Description: Sets the start for the SIC telegram (p60122) in the send words (r2051, r2061).
Dependency: Refer to: p0922, p2079, p60122
Note: For setting p0922/p2079, the value is preset to the end of the PZD telegram.
For p0922 equal to 999 and p2079 not equal to 999, the preset value can be increased.
The value must be set again after changing p0922/p2079.
Description: Displays the PROFIBUS address of the sender from which the process data (PZD) is received.
Index: [0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
Note: Value range:
0 - 125: Bus address of the sender
65535: not assigned
25 Bit 25 ON OFF -
26 Bit 26 ON OFF -
27 Bit 27 ON OFF -
28 Bit 28 ON OFF -
29 Bit 29 ON OFF -
30 Bit 30 ON OFF -
31 Bit 31 ON OFF -
r2067[0...1] PZD maximum interconnected / PZDmaxIntercon
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
p2071 PROFIdrive SIC start send / SIC start send
CU240E-2_DP_F
CU240E-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned8
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 2423
Min Max Factory setting
0 12 0
r2074[0...11] PROFIdrive diagnostics bus address PZD receive / Diag addr recv
CU240B-2_DP
CU240E-2_DP
CU240E-2_DP_F
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -