Note: KHP: Know-How Protection
Even if know-how protection is set, parameters in this list can be read and written to.
Description: OEM exception list (p7764[0...n] for setting parameters that should be excluded from know-how protection.
p7764[0...n], with n = p7763 - 1
Dependency: The number of indices depends on p7763.
Refer to: p7763
Note: KHP: Know-How Protection
Even if know-how protection is set, parameters in this list can be read and written to.
Description: Setting for activating/de-activating copy protection for the memory card.
This means that the OEM can define whether the parameters and DCC data encrypted on the memory card should
be protected before using on other memory cards.
Value: 0: Deactivating protection
1: Activating protection
Dependency: Refer to: p7766, p7767, p7768
Note: KHP: Know-How Protection
The memory card copy protection is only effective when the know-how protection has been activated.
Description: Sets the password for know-how protection.
Example of a password:
123aBc = 49 50 51 97 66 99 dec (ASCII characters)
[0] = character 1 (e.g. 49 dec)
[1] = character 2 (e.g. 50 dec)
...
[5] = character 6 (e.g. 99 dec)
[29] = 0 dec (completes the entry)
Dependency: Refer to: p7767, p7768
Notice: An ASCII table (excerpt) can be found, for example, in the appendix to the List Manual.
When using the STARTER commissioning software, the password should be entered using the associated dialogs.
p7764[0...n] KHP OEM exception list / KHP OEM excep list
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: U, T Scaling: - Dyn. index: p7763
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 65535 [0] 7766
[1...499] 0
p7765 KHP memory card copy protection / KHP copy protect
Access level: 3 Calculated: - Data type: Integer16
Can be changed: U, T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 1 0
p7766[0...29] KHP password input / KHP passw input
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: U, T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -