Data Sheet for Product

Siemens Data Sheet 9904
Smart Infrastructure Building Products usa.siemens.com/fire
Cerberus® PRO
Detectors and Peripherals
Multi-Criteria Fire Detector [with ASAtechnology™]
Model OOH941
Model OOH941
Multi-Criteria Fire Detector
[with ASAtechnology]
Product Overview
Model OOH941 is an advanced, flexible multi
-
criteria fire detector that incorporates
a redundant optical / thermal sensor. Additionally, Model OOH941 utilizes
ASA
technology a distinctive forward / backward, light-
scattering technology that
provides
high-tech, unparalleled fire detection to the widest range of fire types
allowing the detector to distinguish non
-threatening deceptive phenomena.
Each Model
OOH941 is UL 268 7th edition listed incorporating advanced built-in
ISO
technology- True Class-
X SLC operation (use is optional) greatly improving
system reliability and circuit integrity while providing advanced addressable fault
finding.
The unit may be
programmed as a high-sensitivity detector, with a 0.2 %/ft Pre-
Alarm threshold and 1.0 %/ft Alarm threshold thus meeting the requirements of
NFPA 76
Standard for the Fire Protection of Telecommunications Facilities
as a
Very Early Warning Fire Detector (VEWFD)
.
Each of these multi
-
purpose, addressable detectors offers a full and modern
solution to meet the detection needs for commercial facilities. Model OOH941
detectors can be field programmed for simultaneous and
/ or independent
functionality, depending upon the precise customer and application requirements.
For example, the detector can simultaneously utilize the optical and heat sensors for
enhanced multi
-criteria fire detection, as well as provide independent
outputs for
heat detection. Any combination of the sensors is possible.
The detector is very versatile, and meets the following fire
-industry standards:
Multi-criteria fire detector ( UL 268 7
th
edition)
Heat detector ( UL 521) with five (5) possible field-selectable
temperatures; combined with four (4) rate-of-rise options
Direct, in-duct (plenum) detector ( UL 268A)
Supervisory monitoring for temperature ranges
NFPA 76 (Telco Standard) as VEWFD
Low-temperature warning signal at 40°F (4.C)
for sprinkler systems, per NFPA 25 / NFPA 72
For instance, the signals from the detector’s
sensors are monitored and processed via the
ASA
patented algorithm technology, which
combines the signals into a neural network to
create an intelligent, mul
ti-criteria addressable
detector.
Architect & Engineer Specifications
UL 268 7
th
edition Listed, ULC Listed; FM
(#3230, #3210), CSFM (#7272-0067:0258)
Approved
Built-in ISOtechnology
Advanced multi-criteria fire detector that
has dual-optical thermal sensors
Differentiates between deceptiv
e
p
henomena and an actual fire (nuisance-
alarm avoidance)
Compatible with `H’-series devices on the
same loop of Cerberus PRO modular
(FACPs)
Provides enhanced detection via
forward-and-backward light-
scattering technology
Complies with NFPA 76 (Telco standard) as
`VEWFD’ high-sensitivity detector
UL Listed and FM Approved as a multi-
criteria and `VEWFD’ fire detector
UL 268A Listed for direct air-duct use
(4,000 FPM)
Supervisory temperature-monitoring
Remote sensitivity-measurement capability
Automatic environment compensation
Up to 22 application profiles
Tri-color detector-status light-emitting
diode (LED)
Polarity insensitive via SureW ire
Low-temperature warning for sprinkler
systems, per NFPA 25
Meets UL, NFPA 72 requirements fo
r
s
ensitivity self-monitoring
Compatible with:
- Model DB-11
series mounting bases
- Model 8720 / DPU (devic
e
p
rogrammer / loop tester)
Restriction of Hazardous
Substances (RoHS compliant)
Responds to both flaming and
smoldering-fire signatures