Operating/installations instructions

18
In case of fault
If your device does not function as intended, it is usually due to a small detail. Please check whether or not the fault can be
self-repaired according to the following indicators.You will thereby avoid the costs of an unnecessary repair service.
In normal operations, the LED “anode” is constantly lit, the LED “service” is off.
If one of the two LEDs flashes, this indicates an “error condition”.
In case of fault, do not disconnect the power supply line.
In order to possibly remedy the error condition oneself, there are two procedures:
RESET: To begin with, please reset the device RESET. To do this, proceed as follows:
Firstly, turn the dial to the setting ”
”.
After that, press the “fast-heating” button .
If the cause of the “error condition” does not exist directly after the reset, the device will again return to its normal mode of
function. Otherwise the device will again indicate an “error condition”.
Diagnostic routines: In order to better define the “error condition”, the device uses diagnostic routines. Please activate the
program as follows:
Push and hold the button “fast-heating” for at least 5 seconds.
The type of fault will now be displayed by the 6 hot water content LEDs , as presented in the following table:
1 2 3 4 5 6
Anode
Service
Fast-heating LED
Fast-heating
button
Heat content display indicators (LED)
Model
Boiler mode operation
Current limits
Secure load
1/N/PE~230V
1/N/PE~230V
1/N/PE~230V
2/N/PE~230V
2/N/PE~230V
2/N/PE~230V
3/N/PE~230V
3/N/PE~230V
3/N/PE~230V
2kW
3kW
4kW
2kW
3kW
4kW
2kW
3kW
6kW
DG80025 - DG15025
2 kW 1/N/PE~230 V // 1 x min 10 A
3 kW 1/N/PE~230 V // 1 x min 16 A
4 kW 1/N/PE~230 V // 1 x min 20 A
2 kW 2/N/PE~230 V // 2 x min 10 A
3 kW 2/N/PE~230 V // 2 x min 10 A
6 kW 2/N/PE~230 V // 2 x min 16 A
2 kW 3/N/PE~230 V // 3 x min 10 A
3 kW 3/N/PE~230 V // 3 x min 10 A
6 kW 3/N/PE~230 V // 3 x min 10 A