User Manual
Display and Operation Units
Multifunction devices
* You can order this quantity or a multiple thereof.
■
Technical specifications
■
Selection and ordering data
1)
The required mounting bracket must be ordered separately.
Additional mounting brackets are available on request in various sizes.
2)
The matching i-system design frame must be ordered separately.
Type Description
UP 227 Room operator unit UP 227
• Multifunctional display/operator panel for KNX with dot-matrix
LCD display, 96 x 128 pixels
• For the display and control of at least 10 adjustable room
operator functions:
- switching on/off/over
- door bell function on/off
- dimming
- solar protection control
- send1 byte/2 byte value
- display 1 bit/1 byte/2 byte value
- forced control
- display text messages
- recall and save scenes
- warning and alarm messaging
• 8 touch-sensitive buttons for horizontal operation, can
be locked and released via the KNX bus
• Green/red LED as orientation light, as status indication or as a
response to pressing a button for the signaling of alarm reports
• A signaler for acoustical alarm reports or as a status of the touch
operation
• Integrated room temperature sensor
• Evaluation and weighting of an external inside temperature
sensor
• Room temperature control configurable as two-step control
and/or continuous control, for exclusive heating operation,
exclusive cooling operation or heating and cooling operation
• Selectable operating modes via the KNX:
- comfort
- pre-comfort
- energy-savings and protection
• Local indication
- of the active operating modes or of automatic or manual mode
- inside temperature or outside temperature
- heating or cooling mode
- dew point alarm
- open windows
• Local switching between
- manual and automatic mode
- comfort, pre-comfort, energy-saving and protection mode
• Adjustable time-limited extension of the comfort mode
• Adjustable room temperature setpoint shifting for comfort mode
• Basic setpoint value of the room temperature for comfort mode
can be set via KNX
• An outside temperature-based temperature setpoint
value tracing in the cooling operation
• Adjustable dead zone between the heating setpoint value and
the cooling setpoint value for comfort mode
• Transmission of controller output(s) either as on/off switching
commands or as control commands in the range 0 ... 100 %
• Local display of the manually selected fan rotational speed or of
the automatic adjustment of the fan rotational speed
• Adjustable fan rotational speed or automatic adjustment of the
fan rotational speed on the controller
• Weekly schedule program for controller operating modes, auto-
matic mode and at the least 8 room control functions
• At the least 40 schedule tasks
• Display and set of the date and time
• User control of LCD background lighting and background color
• Display system settings and room temperature controller in the
languages: German, English, French, Italian or Spanish
• User setting of at least 3 operating languages
• Integrated bus coupling unit
• Bus connection via bus terminal
• Flush-mounting device for the mounting in an flush wall box
Ø60mm
• Flush-mounting device in an installation box, Ø 60 mm, with
spring-clip attachment in mounting bracket AQR2500NF to be
ordered separately
• Dimensions (H x W x D): 55 x 55 x 37.2 mm
Type Version DT Order-No. Price
per PU
PU
(UNIT,
SET,
M)
PS*/
P. unit
PG Weight
per PU
approx.
kg
5WG1 227-2AB11
UP 227 Room operator unit UP 227
1)2)
A 5WG1 227-2AB11 1 1 ST 0,050
incl. bus coupling unit
Titanium white
Accessories
S55720-S 161
AQR2500NF Mounting plate
Dimensions (W x H) 70.8 x 70.8 mm
A S55720-S 161 1 1 ST 0,025
SO_PI_Raumbediengerät_UP-227_en.fm Seite 3 Montag, 18. Februar 2013 3:51 15