DANGER MANAGEMENT SYSTEM Terminal systems (Up-grade CS100) ÉÉÉÉ ÉÉÉÉ ÉÉÉÉ Document no. e927 5.
DMS 7000 Inh–e927 5.92 System console MA7003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DMS 7000 System console MA7003 Danger management system DMS7000 display and operating unit for the display of information in plain language. Guided operation and standardized display Accurate information on alarm location and operating status Events are displayed geographically in the sequence: room, floor, building, and general location.
DMS 7000 Functions Monitoring Control Observation Operation Logging Filing Remote transmission Configuration Fire Extinguishing Intrusion Gas Building service Basic Risk sectors: Monitoring Detection-/control elements Detection-/control zones Peripheral equipment: – remote transmission, logging printer etc. Power supply Battery Presence of equipment Communication network – data base: process-/building/equipment image – max.
DMS 7000 System console MA7013 Danger management system DMS7000 display and operating unit for text and graphics Guided operation and standardized display Accurate information on alarm location and operating status Events are displayed geographically in the sequence: room, floor, building, general location Serial interface to central processor ËË Ë ËË Ë ËË ËËËË ËËËË Basic display – ALARM – FAULT – STATUS Light pen Function keys – BUZZER OFF – ACKNOWLEDGE – RESET Destinat.
DMS 7000 Operation (Continuation functions) Basic operation: Buzzer off, Acknowledgement, reset via function keys with guided operation Extended operation: From acknowledge ..... to detection/control elements ”on/off; active/inactive” Roll, turn pages, cursor movement, selection of elements and functions etc.
DMS 7000 Danger Management System DMS 7000 System overview System console MA7013 Central processor Satellite control units MC7033 MC7003 ËË Ë Ë ËË ËËË ËËË C1 C2 CZ10 Fire C3 C4 C5 Netzwerk CZ12 Intrusion System console MA7003 C6 C7 CC4 ( CZ4* ) System printer MP...
DMS 7000 Devices on the ”Central Evaluation Level” General technical data Processor – data bus,pulse – main memory – operating system – file system 16/32bit, 8Mh pulse frequency max. 13M bytes CERTOS real time, multi-tasking MS-DOS 19” module concept MC70.. Central processor central processor for central monitoring and control of the danger management system.
DMS 7000 Terminalsystems Combinations Central processor System console MA7003 Text 4000 names, 4 end interfaces to system console printer End interfaces Frontinterface Network MC7003 1 MC... MA70.. /MP.... 2 3 4 controls remote transmission MF7013 12 programmable Outputs DMUX Printer MP... Power supply Emergency power MC... 220VAC/24VDC or Central processor System console MA7013 52,000 names, 8 end interfaces Text & Graphics MC7033 ËË MC...
DMS 7000 MC7033 Network CERBAN or CERLOOP max. 8 serial interfaces CERTER for the periphery – system console MA7003 text – system console MA7013 text and graphics (provisional solution) – printer Disk drive for data security ON/OFF interface controlled in modular concept – max. 4 floppy disks each with 720kB – max. 2 hard disks 40MB Storage capacity approx. 52,000 nodes (names) integrated DMUX module MF7013 integrated MUX/DMUX module MF7023 MF70..
DMS 7000 MA70.. System-/Operation-console system console for information display and guided operation of the danger management system.
DMS 7000 Danger Management System DMS7000 Replacement of the CS100 The MC7033 central processor and the MA7013 system console are the result of specific new development projects in control centre technology. The equipment forms part of the new DMS 7000 danger management system. New systems of the same complexity as the well-known CS100 equipment family, as well as the modernization of existing CS100 systems form the field of application.
DMS 7000 Organization – The organization of the control unit (day/night, present/absent) can be seen in the system overview on the monitor and can be operated direct. Macro instruction – Data points which are important for the customer can be so defined that they are shown in the system overview and can be operated direct. Circuits for several zones can thus be combined and switched on and off much easier via a macro instruction. Up to 6 spare macro instructions can also be defined.
DMS 7000 Central processor – Data bus, pulse – Address capacity – Operating system 16/32 bit, 8MHz frequency 16 M bytes CERTOS real time, multitasking MS-DOS file format – The file format guarantees flexible working with corresponding OFF line editors. This greatly reduces work time. Although the MS-DOS file format is used, the DMS7000 equipment PC/MS-DOS is virus-proof (operating system CERTOS). DMUX module MF7013 and DMUX/MUX module MF7023 – Provides links (AND, OR etc.