Specification

Branch Circuits Indoor Enclosure  NEMA Type 1 Outdoor Enclosure  NEMA Type 3R
Max. QP Catalog Number Dimensions Dimensions
Ampere 1-Pole No. No. of Max Replace Suffix F (Flush) Std. (inches ) Catalog Std. (inches)
Rating of Spaces Circuits 2-Poles with S for Surface Mounting Pkg Height Width Depth Number Pkg. Height Width Depth
1Phase, 3 Wire SN, 4-24 Circuits / 100-200 Amperes, Aluminum Bus, Rated 100,000A IR
100 12 24 6 E1224ML1100FG 1 14-3/4 12-3/8 3-7/8
125 4 8 2 E0408ML1125F  5 12-5/8 6-5/8 3-1/2 W0408ML1125  5 12-1/4 6 4-1/4
125 4 8 2 W0408L1125SPA50 1 12-14 6 4-1/4

125 8 16 4 E0816ML1125F  1 14-3/4 12-3/8 3-7/8
200 4 4 2 W0404MB1200CT 1 20 11-1/8 4-3/4
1Phase, 3 Wire SN, 16-24 Circuits / 100-225 Amperes, Copper Bus, Rated 100,000A IR
100 10 20 4 E1020MB1100FCGP 1 14-3/4 12-3/8 3-7/8
100 12 24 6 E1224ML1100FCU 1 14-3/4 12-3/8 3-7/8
125 8 16 4 E0816ML1125FCU 1 14-3/4 12-3/8 3-7/8 W0816ML1125CU 1 14-3/4 12-1/8 4-1/4
225 W0406ML1125CU
1 23 10 4-1/8
FEATURES
Interiors offer removal in seconds
Single phase
One piece bus bar construction designed for use
only with circuit breakers
UL Listed
Main lugs and neutral on same plane, same drive
Simple deadfront adjustment after trim is installed
UL listed on 60/75°C conductors (see equipment
markings for applications)
Positive load side circuit breaker hook rails
Main Lugs with Aluminum Bus and Copper Bus 100,000A IR
416 circuits, 100225 Amperes EQ Load Centers with main lugs feature
1 Phase, 3 Wire, SN 120/240 Volts AC a combination trim box in one package.
EQ
®
Load Centers
Breaker Used Indoor Enclosure  NEMA Type 1 Outdoor Enclosure  NEMA Type 3R
Frame Ampere No. of Catalog Std. Dimensions (inches) Catalog Std. Dimensions (inches)
Type Rating Poles Number Pkg. Height Width Depth Number Pkg Height Width Depth
1 Phase, 3 Wire SN  120/240 Volts AC
60 1-2 E0204ML1060S 5 9 -7/8 5-1/8 2-5/8 W0204ML1060 5815 4-1/4
QP, QPH, 100 2 1 17-1/8 7-3/8 4-5/16 W0202MB1100CU 1 17-3/8 7-5/16 4-5/16
HQP 125 2 E0204ML1125SCU 1 17-1/8 7-1/8 4-1/4 W0204ML1125CU 1 17-1/8 17-3/8 4-5/16
200 2 W0202ML1200CU 1 19-3/4 8-3/8 4-5/8
200 2 W0202MB1200CU 1 19-3/4 8-3/8 4-5/8
QPP, QPPH, 225 1-4 W0406ML1225CU 1 23 10 4-1/8
HQPP, QP
QJ2, 150 2 WB2150B 12717-3/8 4-15/16
QJH2, 200 2 WB2200B 12717-3/8 4-15/16
QJ2-H 225 2 WB2225 12717-3/8 4-5/16
3 Phase, 3 Wire 240 Volts AC or 3 Phase, 4 Wire SN  120/208 Volts AC, 120/240, 240 Volts AC
QP, QPH,HQP 100 2-3 E0303ML3100S 1 17-1/8 7-1/8 4-1/4 W0303ML3100 1 17-1/8 7-3/8 4-5/16
BQ, BQH, HBQ 100 2-3 EB3100S 1 17-1/8 7-1/8 4-1/4 WB3100 1 17-1/8 17-3/8 4-5/16
QJ2, QJH2, 225 2-3 EB3225F 127111 10-1/8 5-1/8 WB3225 1 27 10-1/8 5-9/16
QJ2-H
FEATURES
Circuit breaker enclosures range from 60A to 225A, indoor and outdoor models.
Designed for use exclusively with QP, QT, QPH, HQP, BQ, BQH, HBQ, QPP, QPPH, HQPP, QJ2,
QJH2 and QJ2-H circuit breakers.
UL listed.
Suitable for use as service entrance equipment.
UL listed for 60/75°C conductors (See equipment markings for applications).
Circuit Breaker Enclosures
Will not accommodate 2-pole GFCI or circuit breaker
with shunt trip.
Main breaker factory installed.
42,000A IR maximum. Copper wire only at 225A.
QJ2 frame circuit breaker installed, rated 10,000A IR
Will not accommodate GFCI or circuit breaker with
shunt trip.
Suitable for use as service entrance when not more
than six main disconnecting means are provided, and
when not used as lighting and appliance branch circuit
panelboard. Check local codes and restrictions.
70 Amp maximum breaker.
100 Amp maximum breaker.
Suitable for use as service entrance equipment when a
main breaker (125A maximum) is back-fed in a branch
position and used with main breaker retainer clip
(Cat. No. MBR1).
Suitable for use as service equipment when a main
breaker (100A maximum) is back-fed in a branch
position and used with main breaker retainer clip
(Cat. No. MBR1).
Includes factory installed QF250 ground fault circuit
breaker and ground bar.
Two Q115 and one Q230 circiut breakers
included.
3
ALL-SITES
TM
Temporary Power Outlet Panels
8
FEATURES
Enclosures
Rainproof
Rainproof NEMA Type 3R construction.
Quality Finish
All sheet metal components are
powder coated with the highest
quality finish and fabricated with
G90 galvanized steel.
Installation Ease
Three raised mounting embosses
make installation a snap.
Removable Deadfronts
Easily removable upper and lower
deadfronts allow easy access to
internal components for ease of
installation.
Theft Resistant
The padlock provisions and elevated
upper deadfront design prevent
unauthorized removal of the plugs
or access to the circuit breakers.
Meters Top or Bottom
Metered units are available with
meters at the top or bottom.
- Ring and ringless type meter
covers available.
- Utility grade, Landis & Gyr meter
socket base.
- Units with meter at bottom are
ideally suited for underground feeds.
- Meter sockets available to 125 amps
maximum.
Removable Door
Sloped door allows additional room
for plugs, and is designed with
aesthetic forms to add rigidity
and sturdiness.
Overhead/Underground Feeds
Surface devices have provisions for
overhead and underground feeds.
- For an overhead feed, use a readily
available Type RX, interchangeable
hub. Closure plate is factory
included.
- For an underground feed, an
extensive variety of easily removable
knockouts are provided.
Light Option
Lighted option to assist with
nighttime site location and operation.
Light provisions are the longest lasting
and have the lowest operating cost in
the industry.
Pedestals
One-Piece Construction
Rigid, one-piece pedestal construction
for all earth and pad mounted
devices. Thoroughly tested for torsion
and flexing resistance.
Block Assembly
Loop-feed block assembly provides
connectors capable of accepting up
to 350 kcmil conductors.
(Available on pedestal devices only.)
Pad Mount
Pad mounted devices are available.
(not shown)
Interiors
Bus Bars
Plated copper bus bars provide the
best protection against corrosion.
Copper Conductors
Ready to use! All internal
components are factory prewired
with copper conductors.
Circuit Protection
All receptacles are protected by life-
time warranted Siemens circuit
breakers.
Receptacles
Impact-resistant, thermoplastic,
commercial grade receptacles.
GFCI Protection
All 125 volt, 20 amp receptacles have
GFCI protection. Siemens GFCI circuit
breakers are available to provide
protection for 20-50 amp receptacles.
Wire Connectors
All wire connectors are suitable for
use with copper or aluminum wire.
(not shown)

