Use & Care Guide

Main Lug / Convertible Load Centers
12-42 Circuits / 125-225 Amperes
Branch Circuits Indoor Enclosure – NEMAType 1
Main Enclosure
Ampere Max. No.of 1-Pole Max. Copper Bus Circuit Breakers Height
Rating Spaces Circuits 2-Poles Catalog Number Enclosed (inches)
1 Phase, 3 Wire SN
125 16 24 8 G1624L1125CP 6 - 20A single pole 21
200 30 40 15 G3040L1200CP 6 - 20 A single pole; 36
1 - 30A double pole;
1 - 50 A double pole
Copper Bus
60 / 75
o
C Rated 100,000A IR
Value Pack (Circuit Breakers Enclosed)
Main Breaker and Main Lug/Convertible Load Centers
Siemens load centers, with a single
main breaker or with main lugs feature
a rigid trim boxed in a separate carton
within the main carton. Other
features include:
A The patent-pending feature
INSTA-WIRE
TM
allows faster
installation because screws are
backed out, ready for wire insertion
B Tabs hold the trim in place during
installation freeing both hands to
drive trim screws
C Patent-pending visible neutral
bar which aids in insertion
of conductors
D Slotted/square drive neutral, trim,
upper pan adjusting, and bond
screws allow increased flexibility
E Inboard, insulated neutral bars
F 140% available neutral positions
G Pre-positioned bond screw saves
installation time and eliminates
lost screws
H All devices convertible from
main breaker to main lug and vice
versa
I All main breakers straight-in wired
(back feed breakers eliminated)
J Rigid, positive locking hook rails in
molded basepan
K Tangential K.O. eliminates the need
for conduit offsets.
Main Breaker / Convertible Load Centers
12-42 Circuits / 100-200 Amperes
Aluminum or Copper Bus
60 / 75
o
C Rated 22,000A IR
Branch Circuits Indoor Enclosure – NEMA Type 1
Main Enclosure
Ampere Max. No.of 1-Pole Max. Copper Bus Circuit Breakers Height
Rating Spaces Circuits 2-Poles Catalog Number Enclosed (inches)
1 Phase, 3 Wire SN
100 10 20 2 E1020MB1100FCGP 2 - 15A single pole
1 - 30A double pole
100 20 20 10 G2020B1100CP 6 - 20A single pole 24
200 30 40 15 G3040B1200CP 6 - 20A single pole 36
1- 30 A double pole;
1-50A double pole
200 40 40 20 G4040B1200CP 6 - 20A single pole 39
1- 30 A double pole;
1-50A double pole
Single phase factory installed 22kA IR main circuit breaker offers 22/10kA IR series combination rating when using
10kA IR Type QP, QT, QPF and QAF branch breakers.
Suitable for use as service entrance equipment.
May be installed on higher rated systems when protected by a circuit breaker with a higher AIR rating.
See equipment markings.
Indoor enclosures are 14-5/16” wide by 3-15/16” deep.
See equipment markings for details.