Data Sheet for Product

XLS Single-Node Upload (SNU) Assembly
6360
s Industry, Inc.
Building Technologies Division
s
Data Sheet
Fire Safety Products
FireFinder® XLS and XLSV
Single-Node Upload (SNU) Module
Models SNU-KIT, SNU-ASSY, PS-5A and PMI-1 UPLD-CBL
Product Overview
Used in conjunction with Siemens FireFinder XLS / XLSV
panels, the Single-Node Upload (SNU) is an optional
system module that provides a solution for uploading /
downloading XLS / XLSV configuration data remotely.
SNU can easily transmit information from a personal
computer running the Z
EUS custom-configuration tool to
a maximum 64 Person Machine Interfaces (PMI).
A dedicated Ethernet connection is the means used to
allow SNU to directly provide information from the Z
EUS
tool to the remotely located PMIs. Additionally, the
Ethernet connection is separate from all existing system
networks (XNET, HNET and DNET), as well as any other
network devices.
A USB connector used in regular Z
EUS communication
also provides the physical connection between each
Model PMI-2 and the SNU module.
However, for XLS fire or voice systems that operate with
the legacy Model PMI interface, a serial cable (Model PMI-1
UPLD-CBL) must be ordered for use with the SNU assembly.
See: Details for Ordering on the following page.
Each SNU module has three (3) connections: Power,
Ethernet and USB. The data transported between
the Z
EUS tool and SNU is made through a direct 128-
bit, Secure Sockets Layer (SSL) connection.
Technical Data
Electrical Ratings
24V Alarm Current: 120mA
24V Standby Current: 120mA
24V Screw Terminal Current: 120mA
24V Back Plane Current: 0
6.2V Back Plane Current: 0
Physical Properties
Dimensions
{ W -x- H -x- D }
8.5’’x 13.3’’ x 2.75’’
(21.6 cm. x33.8 cm. x7 cm.)
Weight Approx. 8 Lbs. (3,629g)
Cost-effective, highly efficient processor designed for
transmitting bidirectional data between the Z
EUS tool
and FireFinder XLS /V panels connected remotely
Allows transferring and extracting of information
stored in the Person Machine Interface (PMI)
Up to 64 XLS / XLSV panels can pass along system
data from as many SNU assemblies
Utilizes a dedicated (128-bit secure) Ethernet cable connection
Universal Serial Bus (USB) cable is used between Model PMI-2
interface modules and each SNU assembly
A serial cable (Model PMI-1 UPLD-CBL) must be ordered for
cable connection between a legacy Model PMI interface
module and each SNU processor
One (1) Universal Serial Bus (USB) cable is included in each
shipment of the SNU assembly
SNU hardware mounts in a separate enclosure,
Model ENCL-01
Each SNU assembly gets continuous power
from an integrated power supply
ARCHITECT AND ENGINEER SPECIFICATIONS
Typical mounting set-up of a
single-node upload module
UL 864 10
th
Edition and UL 1076 Listed;
ULC-S527 3
rd
Edition Listed, CSFM
(
#
7165-0067:02222) and NYCFD
(
#
6160A) Approved