Technical data

1.5.14 Interrupt Source Flag Register
15 14 13 12 11 10 9 8 No. Initial value
Reserved 29 0000H
7 6 5 4 3 2 1 0
INT7 INT6 INT5 INT4 INT3 INT2 INT1 Reserved
Table 39: Interrupt Source Flag Register Overview
Bit position Bit name R/W Function
15:8 - R Reserved
Ignore on read access
7 INT7 R INT7
Indicates, if the ENERGYON bit has been set
INT7 Energy detection interrupt
0
b
No sufficient energy level detected (initial value)
1
b
Sufficient energy level detected
6 INT6 R INT6
Indicates, if auto-negotiation process has been completed
INT6 Auto-negotiation completion interrupt
0
b
uto-negotiation has not been completed
(initial value)
1
b
uto-negotiation has been completed
5 INT5 R INT5
Indicates, if a remote fault condition has been detected
INT5 Remote fault detection interrupt
0
b
No remote fault condition has been detected
(initial value)
1
b
Remote fault condition has been detected
4 INT4 R INT4
Indicates, if a link down situation has been detected
INT4 Link down interrupt
0
b
No link down interrupt has been generated
(initial value)
1
b
Link down interrupt has been generated
Copyright © Siemens AG 2008. All rights reserved. Page 48 ERTEC 200 PHY
Technical data subject to change Version 1.0.0