Technical Manual
Table Of Contents
- 1 About this document
- /
- The information provided in this manual is a summary of the key procedures and functions required to assemble, install, operate, commission and repair the system.
- It is intended to provide experienced and qualified personnel a guide on the required processes.
- The technical manual applies to the Cerberus FIT fire control panel FC12x series.
- The information in this document is intended for the following target groups:
- The reference document has the following designation:
- ID_x_en_--
- x = version, en = English, -- = international
- The list below is used as a reference for the fire control panel FC12x and as a supplement to this document.
- Version
- Edition date
- Brief description
- 2 Safety regulations
- 3 System description
- /
- 4 Installation
- 5 Function overview
- 6 Operation
- AVC
- DIRECT
- Manned
- Unmanned
- The actual events will display all pending events.
- The panel is protected against unauthorized user operation.
- Therefore enter the password or turn the key switch (optional).
- The panel is protected against unauthorized user operation. Therefore enter the password or turn the key switch (optional).
- The alarm counter counts all fire alarms.
- All events such as alarm(s), fault(s), isolation(s), input(s) and output(s) activation are stored in a history log.
- Manual logout to access level 1.
- Each zone can be isolated individually.
- Enable the test mode for each zone.
- Disable outputs generally and / or individually.
- Information about the software is displayed.
- Exit with
. - Exit with
. - Exit with
. - 7 Programming
- Input customer text for:
- 8 Tool function
- 1. Start the Hyper Terminal and enter an appropriate name.
- 2. Select communication port.
- /
- Make sure your PC is connected to the FDUZ22x box and the driver is installed.
- /Make sure your PC is connected to the FDUZ22x box and the driver is installed.Check the communication port on the device manager.
- /
- /
- 1. Select the following option on the panel.
- 2. Enable the Hyper Terminal to receive data.
- /
- /
- /
- /
- /
- 1. Select the following option on the panel.
- 2. Enable the hyper terminal to receive data.
- /
- /
- /
- /
- /
- 1. Select the following option on the panel..
- 2. Enable the hyper terminal to 'Send file'.
- /
- /
- /
- 1. Click
. - 2. Select the folder 'Settings' and click 'ASCII Setup'.
- 5. PC will display as below. Press '2'.
- 6. 'CC…' shows the connection is established and ready for transfer.
- /
- /
- /
- 9 Commissioning
- 10 Maintenance
- 11 Battery capacity
- 12 Trouble shooting
- 13 Components and spare parts
- 14 Disposal and environmental protection
- Appendix A: Site configuration, Factory Setting
- Appendix B: Switch mains to AC 115 V
- Appendix C: History log
A6V10393190_j_en_-- 85
Appendix A: Site configuration, Factory Setting
Customer: ____________________________________________________________
Description Default
Zone 123456789101112
Yes
No
No
No
No
Yes
No
No
No
Output 123456789101112131415
Out 1
Out 2
Out 3
Fire output No
No
EN 54-13 supervision
Out 1,2
Out 3
123
Input 1
Input 3
Input 2
Accessory
Output card No
No
No
EVAC module No
Zone indication field No
Key switch set No
Ext. powered
Card 1
Card 2
Class change signal
Dependency reset
Sounder control
Alarm dialer
Fault dialer
EVAC Sounder NL
General Alarm
Active by zone alarm
General Alert
Active by zone alert
Alert by ext. input
Disable dialer outputs
Manned / unmanned
Toggle manned / unmanned
External PSU fault
Alarm dialer fault
Dialer device confirmation signal
Activate alert mode
ACK
SE ACK function
Reset
AVC
Mode
Activation
condition
Card 3
Date of Installation: ____________________
Control panel:
FC121-ZA (2 zones) /
FC122-ZA (4 zones) /
FC123-ZA (8 zones) /
FC124-ZA (12 zones)
Standard
Mixed MCP & det.
Menu On side programming
Pulse time
Mode
Y / N
GB continuity
Short = alarm
Direct
Via V1 / V2
Via AVC timer MCP direct
Device coincidence
Zone coincidence (zone pairs; 1&2, 3&4, etc.)
Level 2 access
Input
Mode
Any isolation
Any fault
Manned mode activated
Alarm dialer fault
Dialer device confirmation signal
V1 / V2 is running