Sinteso™ Fire control panel FC2020 Compact, pre-assembled fire control panel with integrated, user-friendly operating unit.
Features and Functions System The diagrams have been simplified and do not include additional network hardware or security components. Permissible applications are described in the A6V101039125 Network Security Guidelines document. Contact your Siemens IT security expert for more information. System overview Fig.
1 Remote access with SintesoView/ Sinteso Touch 2 FS cloud applications 3 Customer network 4 Management platform 5 Remote access to management platform 6 Remote access with Sinteso Mobile 7 Router + firewall + virtual private network 8 Fire damper with actuator Transmission of a fault signal Transmission of an alarm signal You will find a detailed labeled version of the diagram above along with further information in the A6V10906627 planning guide, see chapter 'Product documentation'.
Networking of fire control panels The diagrams have been simplified and do not include additional network hardware or security components. Permissible applications are described in the A6V101039125 Network Security Guidelines document. Contact your Siemens IT security expert for more information. Up to 32 control panels and terminals can be linked to form one FCnet network. If the FCnet network is connected to a danger management system via BACnet, up to 16 control panels and terminals can be networked.
Fig. 3: Backbone 1 Remote access with SintesoView/ Sinteso Touch 2 FS cloud applications 3 Customer network 4 Management platform 5 Remote access to management platform 6 Remote access with Sinteso Mobile 7 Router + firewall + virtual private network Transmission of a fault signal Transmission of an alarm signal You will find a detailed labeled version of the diagram above along with further information in the A6V10906627 planning guide, see chapter 'Product documentation'.
Control panels General features and functions ● Fast Ethernet interface for a heterogeneous network ● Processes the signals of the Sinteso detector series FD20 ● Floor repeater displays, terminals and alarm devices on the FDnet detector line with power supply via FDnet ● Interface to Siemens danger management system ● Slots for RS232 and RS485 serial interfaces ● All detector lines are monitored for ground faults ● Integrated degraded mode function ● Freely configurable, time-dependent controls with optiona
FC2020-EZ Housing (Standard) Detector line (FDnet) ● 252 addresses ● 2 loops/4 stubs Properties ● Operating unit (+LED indicator) ● 70 W power supply ● Max. battery capacity 12 Ah Options of the operating unit ● Key switch (Kaba) FTO2005-C1 ● Key switch (nordic) FTO2006-B1 FC2020-AA Housing (Comfort) Detector line (FDnet) ● 252 addresses ● 2 loops / 4 stubs Properties ● Operating unit ● Operating add-on (empty) ● 150 W power supply ● Max.
Extensions You will find information on the integrated extinguishing system and the individual extinguishing components that are available in a separate data sheet with the document ID 'A6V10880701'.
FH2004-A1 Housing (Large Extension) ● ● ● ● Empty housing for free use 430 x 398 x 265 mm E.g., for extra batteries, operating add-ons, or event printer Space for the following battery configurations: – 2x FA2007-A1 (45 Ah) or ● FH2005-A1 – 2x FA2008-A1 (65 Ah) The mounting kit for the batteries FHA2061-A1 must be ordered separately. Housing (Large) ● ● ● ● Empty housing for free use 430 x 796 x 265 mm E.g.
DL3750+ Matrix printer (external) ● ● ● ● External matrix printer recommended by Siemens Supports monitoring for printing faults Can be controlled via the RS232 module FCA2001-A1 (order separately) Can be controlled via Ethernet via the print server PS104 from SEH Use For smaller-scale applications, e.g., workshops or hotels. Also suitable for more comprehensive systems thanks to flexible networking options.
Design Function elements Operating unit The following elements are available on the operating unit: ● CPU module and electronics ● Ethernet connection ● Slots for RS232 and RS485 modules and network modules (SAFEDLINK) ● Space for 'Kaba' or 'nordic' key switch ● Space for event printer (depending on version) ● Peripheral data bus connection for optional LED modules Periphery board From MP8, the fire control panels can be ordered with a periphery board with a 0.5 A or 1.5 A output current per FDnet line.
Setup FC2020 inside housing (Standard) Fig. 4: FC2020 Standard Position Designation Type Comment Items 1-5: Basic equipment for each FC2020-xx in housing (Standard). The periphery board (2 loops, P) can be ordered separately to convert the station to the 1.5 A FDnet line.
Position Designation Type Comment Extensions 7 Relay module Z3B171 Relay for fire controls 8 Event printer FTO2001-A1 For logging events 9 Key switch (Kaba) FTO2005-C1 For operating access authorization Key switch (nordic) FTO2006-B1 10 Mounting plate FHA2007-A1 e.g.
FC2020 inside housing (Comfort) Fig. 5: FC2020 Comfort Position Designation Type Comment Items 1-5: Basic equipment for each FC2020-xx in housing (Comfort). The periphery board (2 loops, P) can be ordered separately to convert the station to the 1.5 A FDnet line.
Position Designation Type Comment 10 Mounting plate FHA2007-A1 E.g., for fire brigade periphery module or Connect X200 Gateway 11 Loop extension (FDnet) FCI2003-A1 For loop extension of the periphery board (2 loops) FCI2002-A1 from two to four loops, number of addresses remains the same Loop extension (FDnet/C-NET, P) FCI2025-A1 For loop extension of the periphery board (2 loops, P) FCI2023-A1 from two to four loops, number of addresses remains the same.
Type Overview Housing (Standard) Type FC2020-AZ Housing (Comfort) FC2020-EZ Number of FDnet addresses FC2020-AA FC2020-AE 252 Number of lines: Loops (with loop extension) or 2 (4) Stubs (with loop extension) 4 (8) Power supply 70 W 150 W Battery size 12 Ah 25 Ah Indicator groups with one red/green and one yellow LED each - 24 - 48 16 Smart Infrastructure 009383_v_en_-2021-10-22
Details for ordering Control panels Type Designation Weight Order number FC2020-AZ Fire control panel (2-loop) 8.537 kg A5Q00015550 FC2020-AZ Fire control panel (2 loops, P) 8.600 kg S54400-C33-A1 FC2020-EZ Fire control panel (2-loop) 8.657 kg A5Q00016827 FC2020-AA Fire control panel (2-loop) 14.869 kg A5Q00016829 FC2020-AA Fire control panel (2 loops, P) 14.928 kg S54400-C33-A6 FC2020-AE Fire control panel (2-loop) 15.
Type Designation Weight Order number FHA2015-A1 FM blind 2HE 5.050 kg A5Q00024621 FHA2016-A1 19" mounting kit 3.000 kg A5Q00020179 FHA2017-A1 FM blind 1HE 3.020 kg A5Q00024719 FN2001-A1 Network module (SAFEDLINK) 0.022 kg A5Q00012851 FN2002-A1 Repeater (SAFEDLINK) 0.105 kg S24236-B2502-A1 FN2006-A1 Fiber network module (SM) 0.792 kg S54400-A109-A1 FN2007-A1 Fiber network module (MM) 0.792 kg S54400-A110-A1 FTO2001-A1 Event printer 0.
Cloud gateway Type Designation Weight Order number CXG3.X200 Connect X200 Gateway 0.300 kg S55842-Z131-A100 FHA2063-A1 Mounting plate (X200) 0.269 kg S54400-B116-A1 FCA2056-A1 Accessory kit + ACDC (X200) 0.200 kg S54400-S115-A1 Type Designation Weight Order number FA2004-A1 Battery (12 V, 12 Ah, VdS) 3.750 kg A5Q00019354 FA2005-A1 Battery (12 V, 17 Ah, VdS) 5.700 kg A5Q00019677 BAT12-25 Battery (12 V, 25 Ah, VdS) 7.
Product documentation Title Document ID System documentation System description 008836 Product data 008837 Planning 008843 Mounting/Installation 008851 System data sheet FS20 – Fire detection system 008955 Data sheets FC2020 - fire control panel 009383 FC2030 - fire control panel for modernization A6V10087532 FC2040 - fire control panel 009384 FC2060 - fire control panel (modular) A6V10087844 FC2080 - fire control panel (19", modular) A6V10275515 FT2040 - fire terminal 009386 FT2080 -
Technical data Fire control panel (2 loops)/(2 loops, P) FC2020 in housing (Standard) Supply Inputs / outputs Mains voltage AC 97…127 V / AC 196…253 V Power supply 70 W Operating voltage DC 20.5…28.6 V Operating current Max. 2.5 A Battery capacity 2x 12 V, max. 12 Ah Battery monitoring Yes Network monitoring Yes Connectable detector series Sinteso (FDnet) Number of addresses Max.
Fire control panel (2 loops)/(2 loops, P) FC2020 in housing (Standard) Ambient conditions Mechanical data Operating temperature -8…+42 °C Storage temperature -20…+60 °C Air humidity (no condensation permitted) ≤95 % rel.
Fire control panel (2 loops)/(2 loops, P) FC2020 in housing (Comfort) Supply Inputs / outputs Mains voltage AC 115 / 230 V +10/-15 % Power supply 150 W Operating voltage DC 21…28.4 V Operating current Max. 5 A Battery capacity 2x 12 V, max. 25 Ah Battery monitoring Yes Network monitoring Yes Connectable detector series Sinteso (FDnet) Number of addresses Max.
Fire control panel (2 loops)/(2 loops, P) FC2020 in housing (Comfort) Mechanical data Dimensions (W x H x D): ● Without cover cap 430 x 796 x 160 mm ● With cover cap 430 x 796 x 183 mm Protection category (IEC 60529) IP30 Color: Approvals ● Housing ~RAL 7035 light gray ● Cover cap ~RAL 9010 VdS G206109 LPCB 126bn/01 FM 3048514 DNV GL (marine) MEDB00003UW 24 Smart Infrastructure 009383_v_en_-2021-10-22
Issued by Siemens Switzerland Ltd Smart Infrastructure Global Headquarters Theilerstrasse 1a CH-6300 Zug +41 58 724 2424 www.siemens.com/buildingtechnologies Document ID 009383_v_en_-- Edition 2021-10-22 © Siemens Switzerland Ltd, 2007 Technical specifications and availability subject to change without notice.