Sinteso™ Fire detection system FS20 Modular, networkable fire detection system for detection, evaluation, sounding an alarm, and extinguishing in the event of a fire.
System System overview The diagrams have been simplified and do not include additional network hardware or security components. Permissible applications are described in the A6V101039125 Network Security Guidelines document. Contact your Siemens IT security expert for more information.
1 Remote access with SintesoView/ Sinteso Touch 2 FS cloud applications 3 Customer network 4 Management platform 5 Remote access to management platform 6 Remote access with Sinteso Mobile 7 Router + Firewall + Virtual Private Network 8 Fire damper with actuator Transmission of a fault signal Transmission of an alarm signal You will find a detailed labeled version of the diagram above along with further information in the A6V10906627 planning guide, see chapter 'Product documentation'.
Features and Functions ● Control panel range with 7 types of station – Microprocessor-controlled fire detection system – Compact and modular fire control panels for between 252 and 5000 addresses – PC-based operation via Fast Ethernet with SintesoView – Integrated BACnet interface – Free control logic – Phased evacuation ● FCnet/SAFEDLINK networking – Redundant networking – Increased safety (degraded mode) – Fast data transfer of up to 315 kbit/s – Maximum of 32 stations ● Extended networks via FCnet/LAN ba
Performance characteristics Optimum use of customer resources ● Individual control panels or an entire network can be operated from a customer PC using the 'SintesoView' visualization software ● Redundancy cabling replaced by fail-safe network nodes ● Floor repeater display and terminals operated on the FDnet detector line High availability ● Remote access via GAP or cRSP ● Efficient troubleshooting thanks to remote transmission of diagnosis data ● Maximum reliability and secure detection ● Auto-configurati
System Applications FS20 is a modular, networkable fire detection system for detection, evaluation, and sounding an alarm in the event of a fire. Due to its high flexibility and interconnectivity, the application spectrum of the FS20 fire detection system ranges from small hotels, restaurants, and workshops to extremely large applications with special requirements for availability and redundancy, such as airports, shopping malls, and large industrial plants.
1 Management platform 2 Remote access to management platform Transmission of a fault signal Transmission of an alarm signal Building Technologies Fire Safety 7 008955_m_en_-2018-09-28
An optical FCnet/LAN network allows up to 14 sub-nets with up to 16 stations to be operated in one network. A maximum of 64 stations is supported in total.
Stations Cross-station features and functions ● Fast Ethernet interface for a heterogeneous network ● Processes signals from Sinteso as well as from earlier detector series ● Siemens danger management system can be connected ● Slots for RS232 and RS485 serial interfaces ● Floor repeater devices, alarm devices, and mimic displays on the FDnet detector line ● All detector lines are monitored for ground faults.
FC2020-EZ Housing (Standard) Detector line (FDnet) ● 252 addresses ● 2 loops/4 stubs Properties ● Operating unit with LED module ● 70 W power supply ● Max. battery capacity 12 Ah Options of the operating unit ● Key switch (Kaba) FTO2005-C1 ● Key switch (nordic) FTO2006-B1 FC2020-AA Housing (Comfort) Detector line (FDnet) ● 252 addresses ● 2 loops/4 stubs Properties ● Operating unit ● Operating add-on (empty) ● 150 W power supply ● Max.
FC2030 FC2030-AA Housing (Comfort) FDnet detector line: ● 756 addresses ● 2 loops/4 stubs ● Can be extended with 2 module bus cards Installable module bus cards (option): ● Line card (FDnet/C-NET) FCL2001-A1 ● Line card (collective) FCL2002-A1 ● Line card (MS9i) FCL2003-A1 ● Line card (AnalogPLUS) FCL2005-A1 ● Line card (interactive) FCL2006-A1 ● Line card (interactive Ex) FCL2007-A1 ● I/O card (programmable) FCI2008-A1 ● I/O card (horn/monitored) FCI2009A1 ● I/O card (remote transmission) FCI2007-A1 Featu
FC2040 You will find information on the integrated extinguishing system and the individual extinguishing components that are available in a separate data sheet with the document ID 'A6V11480005'. FC2040-AA Housing (Comfort) FDnet detector line: ● 504 addresses ● 4 loops/8 stubs Features: ● Operating unit ● Operating add-on (empty) ● 150 W power supply ● Max.
FC2040-AG Housing (Comfort) Detector line (FDnet) ● 504 addresses ● 4 loops/8 stubs Properties ● Operating unit ● Operating add-on (4xLED indicator) ● 150 W power supply ● Max. battery capacity 25 Ah Options of the operating unit ● Event printer FTO2001-A1 ● Key switch (Kaba) FTO2005-C1 ● Key switch (nordic) FTO2006-B1 FC2040-GA Housing (Large) Detector line (FDnet) ● 504 addresses ● 4 loops/8 stubs Properties ● Operating unit ● 150 W power supply ● Max.
FC2060 FC2060-AA Housing (Large) FDnet detector line: ● Max.
FC2080 ● ● ● ● ● ● ● ● ● ● ● ● FH2080-AA System with multiple redundancy Optionally available with redundant main processor Automatic recognition and addressing of module bus cards Turbo isolation in the event of a short-circuit to ensure uninterrupted availability of FD20 devices Processes signals from Sinteso as well as from earlier detector series Siemens danger management system can be connected Supplied with the following pre-fitted interfaces: – 2x integrated FCnet interfaces – 1x separate Ethernet
Features of the basic components FCC2002-A1 Processor unit (19", FC2080) ● ● ● ● ● ● ● FHA2022-A1 Carrier (19", power supply) ● ● ● ● ● 16 Building Technologies Fire Safety Basic component for the FC2080 Already pre-mounted in the housing (19", pedestal cabinet) FH2080-AA Incl. cable kit for connecting an optional operating unit Includes 19" carrier with cable duct, a card cage (CPU), and a card cage (5 slots) Incl.
FT2040 ● ● ● ● ● ● FT2040-AZ Person Machine Interface that is used remotely from the control panel, which can be optionally provided with its own power supply Up to five fire terminals can be configured with system-wide visibility. The fire terminal has spaces for installing optional interfaces such as an RS232 or RS485, network modules (SAFEDLINK), and a key switch. Each fire terminal has an Ethernet connection.
FT2080 FT2080-A1 Fire terminal (Touch) Detector line (FDnet): ● None Features: ● 12" screen (Touch) EN 54-2-compliant Extra components ● Fire terminal board FTI2001 Can be installed in: ● 19" pedestal cabinet with FC2080 ● Housing (Eco) FH2001-A1 ● Rear cover (FT2080) FHA2039-A1 ● Desktop housing (FT2080) FHA2040-A1 ● Third-party housing with rear cover (FT2080) FHA2039-A1 National extensions Extension Country / region Control panel for fire controls ● France Evacuation operating panels ● ● France
Station application FC2020 This fire control panel is ideal for smaller applications, e.g., for use in workshops or hotels. Thanks to the flexible networking options, the Station can also be used for large-scale sites. FC2030 This fire control panel is ideal for medium-sized applications, e.g., for use in industrial plants, regional banks, or office complexes. Within the context of modernization, the Station allows a gradual and seamless transition from older systems to Sinteso.
Application matrix Use FC2020 FC2030 FC2040 FC2060 FC2080 FT2040 FT2080 Smaller applications, such as workshops or hotels ● ○ ● ○ ○ ‒ ‒ Medium-sized applications, such as medium-sized industrial plants, regional banks, or medium-sized office blocks ○ ● ● ○ ○ ‒ ‒ Large applications, such as industrial plants, large office blocks, or production halls ○ ○ ○ ● ● ‒ ‒ Large applications with high redundancy requirements, such as airports, power generation facilities, and shopping m
Type Overview Fire control panels You will find detailed information on the available control panel types and the available variants in the separate data sheet for the respective control panel type and in the system documentation. You will find information on the document ID of the documents in section 'Product documentation [➙ 28]'. FC2020 FC2030 FC2040 FC2060 FC2080 Standard/ Comfort Comfort Comfort/Large Large 19" pedestal housing Power supply 70 W/150 W 150 W 150 W 150 W Max.
FC2020 FC2030 FC2040 FC2060 FC2080 Integrated outputs for alarm and control: ● RT alarm relay 1 1 1 1 ● RT fault relay 1 1 1 1 ● Monitored alarm output 1 1 1 1 ● Monitored fault output 1 1 1 1 1/4 1/8 2/8 2/8 ‒ 8 8 12 12 ‒ With cover cap/door 430 x 398 x 160 mm 430 x 796 x 183 mm 430 x 796 x 160 mm 430 x 796 x 260 600 x 2200 x 615 mm mm incl.
Fire terminals You will find detailed information on the available terminal types and the available variants in the separate data sheet for the respective terminal type and in the system documentation. You will find information on the document ID of the documents in section 'Product documentation [➙ 28]'.
Accessories You will find information on accessories and possible extensions in the separate data sheet for the respective control panel or terminal type and in the system documentation. You will find information on the document ID of the documents in section 'Product documentation [➙ 28]'.
● Extension possible ‒ Extension not possible 1) Installation is only possible if there is sufficient space in the housing. 2) As an operating add-on in conjunction with an optional operating unit.
Line devices Fire detector ● ● ● ● Fire detectors with the latest generation of evaluation algorithms. Signals are processed using ASAtechnologyTM. Time-dependent and process-dependent detection behavior. Maximum detection reliability thanks to unique detector properties.
Input and output modules ● ● ● ● Statuses can be monitored using an input module, e.g., door monitors, fan controls, or for the activation of sprinkler alarms. Input/output modules are used for the decentralized controls of fire safety doors, fans, and similar applications. The inputs can be used for confirmation purposes, for monitoring statuses, or for controlling the standard extinguishing interface (SST) in accordance with VdS.
Details for ordering You will find ordering information in the separate data sheet of the respective control panel or terminal type and in the system documentation. You will find information on the document ID of the documents in section 'Product documentation [➙ 28]'.
Notes Safety CAUTION National safety regulations Failure to comply with national safety regulations may result in personal injury and property damage. ● Observe national provisions and comply with the appropriate safety regulations. Disposal The device is considered an electronic device for disposal in accordance with the European Guidelines and may not be disposed of as domestic garbage. ● Dispose of the device through channels provided for this purpose.
Technical data You will find information on the technical data of the individual fire control panels and fire terminals in the separate data sheet for the respective control panel or terminal type. You will find information on the document ID of the documents in section 'Product documentation [➙ 28]'. Issued by Siemens Switzerland Ltd Building Technologies Division International Headquarters Theilerstrasse 1a CH-6300 Zug Tel. +41 58 724 2424 www.siemens.