User Manual

5
4
1
3
7 2
6
10
8
9
www.siemens.com/firesafety
Siemens Switzerland Ltd
Infrastructure & Cities Sector
Building Technologies Division
International Headquarters
Gubelstrasse 22
6301 Zug
Switzerland
Tel +41 41 724 24 24
The information in this document contains general descriptions of technical options available,
which do not always have to be present in individual cases. The required features should therefore
be specified in each individual case at the time of closing the contract.
© Siemens Switzerland Ltd, 2013 • BT_0035_EN
We are the trusted technology partner for
energy-efficient, safe and secure buildings and
infrastructure.”
Answers for infrastructure and cities.
Our world is undergoing changes that force us to think
in new ways: demographic change, urbanization, global
warming and resource shortages. Maximum efficiency
has top priority – and not only where energy is concerned.
In addition, we need to increase comfort for the well-being
of users. Also, our need for safety and security is constantly
growing. For our customers, success is defined by how
well they manage these challenges. Siemens has the
answers.
Fire safety solutions for clean rooms
Planning Tool
Point type fire detectors
Sinteso S-LINE detectors FDO241 or FDOOT241-9 are used
in the clean room area. The ASA parameter sets provide
unsurpassed detection security to ensure early recognition
in clean rooms and service areas. A technique, so reliable
that Siemens offers a Genuine Alarm Guarantee for Sinteso
S-LINE fire detectors.
5
Ex zone devices
To guarantee continuity in case of power failure, a data
center is always connected to an uninterruptible power
supply (UPS). In explosion-hazard areas, such as pills
production, battery rooms and solvent storage, Ex devices
have to be used.
Voice alarm system
In case of fire, the voice alarm system E100 is automatically
activated by the fire detection system. It ensures that the
clean room and neighboring areas are evacuated in a safe
and orderly manner. In addition, safety messages and clear
instructions can be transmitted to ensure the cleanness
class.
2
Aspirating smoke detection
The highly sensitive system based on the optical dual-
wavelength detection technology for the earliest possible
fire detection in highly ventilated clean rooms, minimizes
the risk of fire damage. In a clean room, it is typically
applied in false floors and ceilings or air ducts.
3
Air sampling smoke detection
The air sampling smoke detection kit monitors smoke
particles within the air duct. Especially recommended
for clean rooms is the monitoring of the fresh air inlet.
4
Manual call poi nts
For immediate manual actuation of an alarm, manual call
points are placed along the exit routes.
6
Automated extinguishing
Sinorix provides the ideal extinguishing solution
facing the risks in clean rooms. For object protection,
Sinorix N
• Ar • CO
offer reliable extinguishing for a
wide range of fire types. In room protection applications,
Sinorix 1230 and Sinorix CDT convince with outstanding
extinguishing performance.
10
Alarm indicators
If a fire detector that is not easily visible triggers an alarm,
the alarm indicator will quickly identify the area in danger,
for example false ceilings or objects.
8
Extinguishing control panels
XC10 combines fire detection and extinguishing control –
either for a single-sector or a multi-sector application. All
relevant incidents are forwarded to connected fire control
panels. It also interfaces with ventilation systems.
1
Flame detectors
In clean rooms where an open flame is expected, such as
pills production or in microelectronics factories, the flame
detector FDF241-9 ensures fastest fire detection.
Sounder and sounder beacon
In the clean room area, the sounder beacon FDS229 is
highly recommended to alert the clean room staff in noisy
environment.
7
Flat detector base
The flat detector bases are recommended in clean rooms to
avoid any gap between detector and ceiling. In addition, the
use of the seal element FDBZ295 is suggested.
Access control
The access control system provides safe and flexible access
authorization to the clean room – sluice and surrounding
area. In highly classified areas, pin code or a finger print
reader are recommended to avoid contamination due to
the batch.
9
Fire control panels
The Sinteso fire control panels convert a fire alarm
into actions for alarm notification, evacuation and
extinguishing. The simple user interface with prompting
texts lets users quickly check the system status, either
locally or by remote access.
Answers for infrastructure and cities.
Fire safety solutions
for clean rooms
Planning Tool

Summary of content (2 pages)