FCI2020-U1 Leased line / city tie module Mounting Installation A6V10334256_b_en_-2014-05-26 Siemens Industry, Inc.
Legal notice Legal notice Technical specifications and availability subject to change without notice. © 2012-2014 Copyright by Siemens Industry, Inc. Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model or design patent are reserved.
Table of contents 1 1.1 1.2 Leased Line / City Tie module FCI2020..........................................................5 Description .......................................................................................................5 Installation ........................................................................................................6 1.3 1.4 FC901 installation .............................................................................................7 Views ....................
1 Leased Line / City Tie module FCI2020 Description 4 Siemens Industry, Inc.
Leased Line / City Tie module FCI2020 Description 1 1 Leased Line / City Tie module FCI2020 1.1 Description The Leased Line / City Tie module FCI2020 is an optional module that can be configured for leased line or city tie functions. It is installed on the periphery board for connection to a remote monitoring station or city (municipal) tie. The periphery board controls and supervises the leased line / city tie module.
1 Leased Line / City Tie module FCI2020 Installation 1.2 Installation The leased line / city tie module FCI2020 is plugged into the periphery board and is screwed down to the back box. Installing the leased line / city tie module 1 Periphery board (250p) or periphery board (500p) 2 2x fixing screw 3 Leased line/city tie module 4 2x threaded sleeve on back box X902 Slot in periphery board X2/X3 Field wiring terminal connections Installation steps 1.
Leased Line / City Tie module FCI2020 FC901 installation 1.3 1 FC901 installation 1. Secure the city tie to the main board using the two provided #4-32 x 3/8 screws. Spacer T1 Detail A T2 2 #4 screws T3 City tie module 2. Connect the city tie cable between city module and main board. T2 T1 T3 7 Siemens Industry, Inc.
1 Leased Line / City Tie module FCI2020 Views From 1 to 4 TP1295,TP1294,TP1293,TP1292 From left to right: TP1295,TP1294,TP1293,TP1292 1 2 3 4 Detail T1 X2 Output 2 Connect to T2 X3 Output 1 Connect to T3 Detail A City tie cabling 1.4 Views F4 1 X3 1 X2 K2 + - K5 F3 K1 + - F2 K3 F1 K4 Printed circuit board view for FCI2020 8 Siemens Industry, Inc.
Leased Line / City Tie module FCI2020 Views 1 Element Des.
1 Leased Line / City Tie module FCI2020 Wiring 1.5 Wiring Leased line wiring + X3 + X2 l l l l l l - + ALARM/TROUBLE LEASED LINE + SUPERVISORY LEASED LINE - All wiring must be in accordance with article 760 of NEC or local building code. Leased line circuits are not supervised. Polarity shown in active state. No signal polarity inversion Ground faults detected at <0.1 Ω. The circuit resistance must be between 2 and 5 kΩ for each switching.
Leased Line / City Tie module FCI2020 FC901 wiring 1.5.1 1 X3 (Output 1), Leased line or City tie l l City tie module: X3 transmits the alarm status Leased line module: X3 transmits alarm and trouble messages Pin Description - (+) output when activated + (-) output when activated Wire size: 12…22 AWG 1.5.2 X2 (Output 2), Leased line X2 (output 2) is only used for leased line supervisory. Not used when module is configured as a city tie.
1 Leased Line / City Tie module FCI2020 Technical data 1.
FCC Statement 2 2 FCC Statement WARNING Installation and usage of equipment is not in accordance with instructions manual Radiation of radio frequency energy Interference to radio communications ● ● Install and use equipment in accordance with instructions manual. Read the following information. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions manual, may cause interference to radio communications.
Issued by Siemens Industry, Inc. Building Technologies Division 8 Fernwood Road Florham Park, NJ 07932 Tel. +1 973-593-2600 www.sbt.siemens.com/FIS Document ID A6V10334256_b_en_-- Edition 2014-05-26 © 2012-2014 Siemens Industry, Inc. Technical specifications and availability subject to change without notice. SAP order no.