Description: Sets the scaling for the acceleration precontrol of the speed/velocity controller.
Dependency: Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Refer to: p0341, p0342
Warning: The acceleration precontrol r1518 is kept at the old value if the ramp-function generator tracking (r1199.5) is active or
the ramp-function generator output is set (r1199.3). This is used to avoid torque peaks. Depending on the application,
it may therefore be necessary to disable the ramp-function generator tracking (p1145 = 0) or the acceleration
precontrol (p1496 = 0).
The acceleration precontrol is set to zero, if the Vdc control is active (r0056.14/15).
Note: The parameter is set to 100% by the rotating measurement (refer to p1960).
The acceleration precontrol may not be used if the speed setpoint manifests significant ripple (e.g. analog setpoint)
and the rounding-off in the speed ramp-function generator is disabled.
We also recommend that the precontrol mode is not used if there is gearbox backlash.
Description: Displays the torque setpoint before entering the supplementary torque.
For closed-loop speed control, r1508 corresponds to the speed controller output.
Dependency: Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Description: Sets the smoothing time constant of the accelerating torque.
Dependency: Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Note: The acceleration precontrol is inhibited if the smoothing is set to the maximum value.
Description: Displays the accelerating torque for precontrol of the speed controller.
Index: [0] = Unsmoothed
[1] = Smoothed
Dependency: Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Refer to: p0341, p0342, p1496
p1496[0...n] Acceleration precontrol scaling / a_prectrl scal
PM330 Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Unit group: - Unit selection: - Func. diagram: 6020, 6031
Min Max Factory setting
0.0 [%] 10000.0 [%] 100.0 [%]
r1508 CO: Torque setpoint before supplementary torque / M_set bef. M_suppl
Access level: 2 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2003 Dyn. index: -
Unit group: 7_1 Unit selection: p0505 Func. diagram: 6030, 6060, 6722
Min Max Factory setting
- [Nm] - [Nm] - [Nm]
p1517[0...n] Accelerating torque smoothing time constant / M_accel T_smooth
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Unit group: - Unit selection: - Func. diagram: 6060
Min Max Factory setting
0.00 [ms] 100.00 [ms] 4.00 [ms]
r1518[0...1] CO: Accelerating torque / M_accel
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2003 Dyn. index: -
Unit group: 7_1 Unit selection: p0505 Func. diagram: 6060
Min Max Factory setting
- [Nm] - [Nm] - [Nm]