SINAMICS G120 CU230P-2 Control Units List Manual (LH9), 01/2013
Description: Setting parameter for the run-time group in which the instance NOT 5 of the inverter is to be called.
Value: 1: Run-time group 1
2: Run-time group 2
3: Run-time group 3
4: Run-time group 4
5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance NOT 5 within the run-time group set in p20306.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantities X0, X1, X2, X3 of instance ADD 2 of the adder.
Index: [0] = Input X0
[1] = Input X1
[2] = Input X2
[3] = Input X3
Description: Display parameter for the output quantity Y = X0 + X1 + X2 + X3 of instance ADD 2 of the adder.
Description: Setting parameter for the run-time group in which the instance ADD 2 of the adder is to be called.
p20306 NOT 5 run-time group / NOT 5 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7216
Min Max Factory setting
1 9999 9999
p20307 NOT 5 run sequence / NOT 5 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7216
Min Max Factory setting
0 32000 780
p20308[0...3] CI: ADD 2 inputs / ADD 2 inputs
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7220
Min Max Factory setting
- - 0
r20309 CO: ADD 2 output Y / ADD 2 output Y
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: PERCENT Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7220
Min Max Factory setting
- - -
p20310 ADD 2 run-time group / ADD 2 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 7220
Min Max Factory setting
5 9999 9999