Installation Instructions

Drill patterns and dimensions
Fitting the
Control Unit
Removing the
Control Unit
Width
Height
Depth 1
13
b
h
Remove / fix cover
(6 screws FSA, 9 screws FSB and FSC)
Remove / fix gland plate
(6 screws FSA, 8 screws FSB and FSC, )
The screws, indicated by the white arrows,
connect the heat sink to the inverter
housing. These screws must not be
loosened or removed.
The FSA variant has a total of 6 screws
and the FSB and the FSC variants have a
total of 9 screws.
Direct sunlight not
allowed!
U2
V2
W2
L1
L2
L3
PE
Mains, Motor and Brake terminals
The Power Modules are fitted with detachable terminals. It can be removed from the Power Module
by pressing the release catch. The connectors are not interchangeable.
T
ightening torques:
FSA: 0.5 Nm ( 4 lbf.in)
FSB: 0.6 Nm ( 5 lbf.in)
FSC: 1.5 Nm (13 lbf.in)
Cable cross sections
FSA: 1.5 … 2.5 mm
2
16 … 14 AWG
FSB: 1.5 … 6 mm
2
16 … 10 AWG
FSC: 6 … 16 mm
2
10 … 6 AWG
*A5E35100000A-AA*
Compact Operating Instructions
SINAMICS G120
Power Module PM230 FSA ... FSC, IP55
接触带电部件会引发生命危险
本设备会传导危险电压。
接触带电部件可能会造成人员重伤,甚至是死亡。
本设备的运行应根据所配备的安装/操作手册中的详细安装和操作说明进行。
警告
Pericolo di morte per contatto con parti sotto tensione
In questo apparecchio sono presenti tensioni pericolose.
Il contatto con parti sotto tensione può provocare la morte o gravi lesioni.
L’utilizzo di questo apparecchio richiede istruzioni dettagliate per l’installazione e
l’esercizio, che sono riportate nel manuale di installazione e d’uso di questo prodotto.
Avvertenza
Peligro de muerte al tocar piezas bajo tensión
En el presente equipo hay aplicadas tensiones peligrosas.
Tocar piezas que están bajo tensión puede provocar lesiones corporales graves o
incluso la muerte.
El funcionamiento de este equipo requiere unas instrucciones de instalación y servicio
detalladas como las que figuran en el manual de montaje o las instrucciones de
servicio del mismo.
Advertencia
Danger de mort en cas de contact avec des pièces sous tension
L'appareil présente des tensions électriques dangereuses.
Tout contact avec des parties sous tension peut entraîner la mort ou des blessures
graves.
La mise en œuvre de cet appareil nécessite les instructions détaillées d'installation et
de service fournies dans le manuel d'installation/de service correspondant au produit.
Attention
Danger to life when live parts are touched
The present device conducts hazardous voltages.
Touching live components can result in death or severe injury.
Operation of this equipment requires detailed installation and operation instructions
provided in the installation/operation manual intended for use with this product.
Warning
Lebensgefahr durch Berührung unter Spannung stehender Teile
Das vorliegende Gerät führt gefährliche Spannungen.
Beim Berühren unter Spannung stehender Teile erleiden Sie Tod oder schwere
Körperverletzungen.
Der Betrieb dieses Gerätes erfordert detaillierte Installations- und Betriebsanwei-
sungen, wie sie im Montagehandbuch / der Betriebsanleitung für dieses Gerät
enthalten sind.
Warnung
Declaration of Conformity
The Declaration of Conformity can be found at the following link:
http://support.automation.siemens.com/WW/view/en/30563514/134200
Siemens AG,
Frauenauracher Str. 80,
DE-91056 Erlangen
Issue 09/2014
Fix with
3 Nm
Fix with
3 Nm
Fix with 3 Nm
Frame
size
Dimensions (mm)
Distances
(mm)
1)
Fixings
Drill pattern
(mm)
Width
Height
Depth
with BOP-2
or blind
cover
with
IOP
Air flow
Screw
Tightening
torque (Nm) b h Above Below
FSA
154
460
256
266
100
100
M4
2.5
132
445
FSB
180
540
256
266
100
100
M4
2.5
158
524
FSC
230
620
256
266
125
125
M5
3.5
208
604
1)
The Power Modules can be mounted side-by-side. Due to tolerance reasons, we recommend a lateral distance
of about 1 mm.