No. Object name Function Number
Bit
Flags
36 C01/17/33/49 >>1,
2nd telegram, switching
On 1 Bit CWT
37 C01/17/33/49 <<0,
switching
Off 1 Bit CT
38 C01/17/33/49 <<0,
2nd telegram, switching
On 1 Bit CT
39 C01/17/33/49, temperature value 2 Byte CRT
40 C01/17/33/49, Brightness value 2 Byte CRT
41 C01/17/33/49, presence 1=presence 1 Bit CRT
... ... ... ... ...
133 C15/31/47/63 >>1,
switching
On 1 Bit CT
134 C15/31/47/63 >>1,
2nd telegram, switching
On 1 Bit CWT
135 C15/31/47/63 <<0,
switching
Off 1 Bit CT
136 C15/31/47/63 <<0,
2nd telegram, switching
On 1 Bit CT
137 C15/31/47/63, temperature value 2 Byte CRT
138 C15/31/47/63, Brightness value 2 Byte CRT
139 C15/31/47/63, presence 1=presence 1 Bit CRT
140 8-bit scene, Scene channel
A-H
recall / save 1 Byte CRWT
141 Scene channel A, switching save 1 Bit CRWTU
142 Scene channel B, solar
protection
save
1 Bit
CRWTU
143 Scene channel C, forced
control
save
2 Bit
CRWTU
144 Scene channel D, 8-bit
value
save
1 Byte
CRWTU
145 Scene channel E, 16-Bit
value
save
2 Byte
CRWTU
146 Scene channel F, switching save 1 Bit CRWTU
147 Scene channel G, solar
protection
save
1 Bit
CRWTU
148 Scene channel H, forced
control
save
2 Bit
CRWTU
149 Scene channel A, switching recall 1 Bit CRWT
150 Scene channel B, solar
protection
recall
1 Bit
CRWT
151 Scene channel C, forced
control
recall
2 Bit
CRWT
152 Scene channel D, 8-bit
value
recall
1 Byte
CRWT
153 Scene channel E, 16-Bit
value
recall
2 Byte
CRWT
154 Scene channel F, switching recall 1 Bit CRWT
155 Scene channel G, solar
protection
recall
1 Bit
CRWT
156 Scene channel H, forced
control
recall
2 Bit
CRWT
157 IR-ID Number 2 Byte CRWT
158 blocking object (buttons
and IR)
disable / enable 1 Bit CRWTU
159 blocking object (IR
presence) disable / enable
1 Bit CRWTU
160
Internal temperature
Value degree °C
2 Byte
CRWT
通用对象
LED 的亮度
Obj Name Function Length Flag
6
Brightness of status
LED‘s
0=min /
1=max
1 bit CRWTU
通过此对象,可以通过总线设置状 LED 的亮度。状态 LED
最小和最大亮度通过各自的参数确定。
13
Brightness
Orientation LED
0=min /
1=max
1bit CRWTU
通过此对象,可以通过总线设置方 LED 的亮度。方向灯的最
小和最大亮度通过各自的参数确定
方向 LED
Obj Name Function Length Flag
20 Orientation LED On / Off 1 Bit CRWTU
20 Orientation LED 8-bit value 1 Byte CRWTU
通过此对象,可以打开或关闭方向灯。如果在参数窗口
General – LED‘s配置了status objectdependent
on value设置,则此对象可见。否则,此对象不可见,因此
没有功能。
状态 LED 闪烁
Obj Name Function Length Flag
27 LED flashing
0=normal /
1=flashing
1 Bit CRWTU
27 LED flashing
1=normal /
0=flashing
1 Bit CRWTU
通过此对象,可以强制状态 LED 闪烁,与状态 LED 的其他设置
无关。
如果通过此对象接收到On报文(对象值 = 1时闪烁被启
用,则所有状态 LED 以约为 0.5Hz 的频率闪烁(1 秒开,1
关)。
如果通过此对象接收到Off报文(对象值 = 0)时闪烁被启
用,则所有状态 LED 以约为 0.5Hz 的频率闪烁(1 秒开,1
关)。
安全/阻止对象
Obj Name Function Length Flag
158
blocking object
(Button pairs and IR)
disable /
enable
1 Bit CRWTU
通过此对象,可根据参数设置启用或禁用按钮的操作功能