设置Status object(状态对象)
Parameter Settings
Behavior of LED when ON
(1)
Off
On
flash slowly (0.3 Hz)
flash moderately (1 Hz)
flash fast (5 Hz)
Behavior of LED when Off
(0)
Off
On
flash slowly (0.3 Hz)
flash moderately (1 Hz)
flash fast (5 Hz)
此参数根据状态对象的值(ON OFF)确定状态 LED 的行为。
总线电压恢复后,通过总线读取状态来恢复状态 LED 的当前状
态。
设置Dependent on value(依赖于值)
Parameter Settings
Display is dependent on percentage value
8-bit value
brightness value
temperature value
16-bit value
Upper limit value
(0...100%) 70
(0...255) 200
(0 ...2000 Lux) 900 Lux
(0 ...40℃) 2°C
(0 ...65535) 0
Lower limit value
(0...100%) 10
(0...255) 10
(0 ...2000 Lux) 4 Lux
(0 ...40℃) 0,5°C
(0 ...65535) 0
Behavior of LED when value
is greater than upper
threshold value
Off
On
flash slowly (0.3 Hz)
flash moderately (1 Hz)
flash fast (5 Hz)
Behavior of LED when value
is between the threshold
values
Off
On
flash slowly (0.3 Hz)
flash moderately (1 Hz)
flash fast (5 Hz)
Parameter Settings
Behavior of LED when value
is lower than lower
threshold value
Off
On
flash slowly (0.3 Hz)
flash moderately (1 Hz)
flash fast (5 Hz)
此参数确定设置Dependent on value下的状态 LED 行为。
参数Upper limit valueLower limit value确定将对象
值范围划分为三个显示范围的两个阈值。
显示范围 1是低于两个限定值中较低值的值范围。
显示范围 2是两个限定值之间(包含两个限定值)的值范
围。
显示范围 3是高于两个限定值中较高值的值范围。
总线电压恢复后,通过总线读取状态来恢复状态 LED 的当前状
态。
Parameter Settings
Short flashing of LED when
LED is dark
No
Yes
如果选择Yes,则状态 LED 周期性闪烁 (0.5Hz) 50ms
以便指明状态,不会像持续点亮的 LED 那样造成干扰。
按钮对 ABCD
注意
用于设置按钮 A1A2B1B2C1C2D1 D2
及按钮对 ABC D 功能的参数选项卡完全相同。因
此,此处仅介绍按钮 A1 和按钮对 A 的设置。
Parameter Settings
Evaluate button pair A as
disabled
button pair
single buttons
此参数确定是禁用两个按钮、共同配置为按钮对还是单独配置
为有各自功能的单个按钮。
参数窗口根据选择而变化,并根据所选功能显示可能的参数和
设置。
如果选择disabled,则无法进一步配置按钮。