Motion detectors
Version Order No.
Selection and ordering data
5TC1546
5TC1546
5TC15460PM
5TC1500
5TC1501
5TC1502
Comfort motion detector tops
same as motion detector top, plus:
The Comfort motion detector top can also be set to short-time duty
This way it is possible, for example, to control acoustic signal transducers
(bells) for the monitoring of an entry door
The operating mode (continuous OFF/automatic/continuous ON) can be se-
lected by means of a slide switch which can also be secured in the auto-
matic position
The delay time can be innitely adj
usted between 10 s and 30 min
Titanium white (similar to RAL 9010)
Platinum metallic (similar to RAL 9007)
m 01.1 thgieh gnitnuoM
Inserts Section Page
Motion detector relay inserts Functions / Motion
Detectors
10/2
Motion detector triac inserts dto.
10/2
Motion detector extension unit inserts dto.
10/3
Technical specications
Sensing angle Approx. 180°
Mounting height 1.10 m
Sensing eld
- 1.10 m lens Approx. 12 m x 12 m
Number of lenses/ lens levels
- 1.10 m lens 18 / 2
Rated voltage ush-mounting inserts
230 V AC, 50 Hz
Operating temperature Approx. -20 ... +45 °C
Delay time Approx. 10 s ... 30 min
Locking time after switch-off Approx. 3 s
Brightness threshold value Approx. 0 ... 80 lux / day mod
e
Sensitivity Approx. 20 ... 100 %
Number of extension units at the
ush-mounting insert
- Motion detector extension units Max. 10
- Mechanical pushbuttons Unlimited