User Manual
10/2
Siemens ET D1 · 2018/2019
10
Motion Detectors
Inserts
Version Order No.
Selection and ordering data
5TC1500
5TC1500
5TC1501
5TC1501
General information
• For claw and screw fixing
• Screw terminals
Motion detector relay inserts
Motion detector relay inserts flush-mounting insert for motion detector tops,
for switching extensive light sources and electrical loads of up to a maximum
of 10 A/230 V.
For tops see section Page
• Design / i-system / Motion Detectors
• Design / DELTA profil/Motion Detectors
• Design / DELTA style/Motion Detectors
Technical specifications
• Rated voltage 230 V AC, 50/60 Hz
• Connected loads
- Incandescent lamp rating 2300 W
- HV halogen lamps 2300 W
- Conventional transformers 1000 VA
- Electronic transformers 1500 W
- Fluorescent lamps, uncorrected 1200 VA
- Fluorescent lamps parallel p.f.
corrected
920 VA
- Fluorescent lamps in DUO circuit 2300 VA
• Extension units
- Number of motion detector
extension unit inserts
10
- Number of mechanical
pushbuttons
Unlimited
- Maximum cable length (total) 100 m
Note Section Page
Switching commands are issued by
the release of the plug-on motion
detector top or by an extension unit.
For further details of tops, see ...
Technical Information /
Motion Detectors /
Motion detector relay
inserts
16/46
Note
Download the operating and mounting instructions from:
http://support.automation.siemens.com/ww/view/en/5tc1500/all
Motion detector triac inserts
• Flush-mounting inserts for motion detector tops for switching
- 230 V incandescent lamps,
- 230 V halogen lamps and
- LV halogen lamps with magnetic transformer
• The lamp is switched on using a gentle soft start
For tops see section Page
• Design / i-system / Motion Detectors
• Design / DELTA profil/Motion Detectors
• Design / DELTA style/Motion Detectors
Technical specifications
• Rated voltage, 2-conductor-
connection
230 V AC, 50/60 Hz
• Connected loads
- Incandescent lamp rating 40 ... 400 W
- HV halogen lamps 40 ... 400 W
- Conventional transformers
including power loss
Max. 400 VA
• Short-circuit protection
- Miniature fuse T 1.6 H 250 V
• Extension units
- Number of motion detector
extension unit inserts
10
- Number of mechanical
pushbuttons
Unlimited
- Maximum cable length (total) 100 m
Note Section Page
Switching commands are issued by
the release of the plug-on motion
detector top or by an extension unit.
For further details of tops, see ...
Technical Information /
Motion Detectors /
Motion detector triac
inserts
16/47
Note
Download the operating and mounting instructions from:
http://support.automation.siemens.com/ww/view/en/5tc1501/all
2/23
5/18
6/20
2/23
5/18
6/20