User Manual

10/2
Siemens ET D1 · 2018/2019
10
Motion Detectors
Inserts
Version Order No.
Selection and ordering data
5TC1500
5TC1500
5TC1501
5TC1501
General information
For claw and screw fixing
Screw terminals
Motion detector relay inserts
Motion detector relay inserts ush-mounting insert for motion detector tops,
for switching extensive light sources and electrical loads of up to a maximum
of 10 A/230 V.
For tops see section Page
Design / i-system / Motion Detectors
Design / DELTA prol/Motion Detectors
Design / DELTA style/Motion Detectors
Technical specications
Rated voltage 230 V AC, 50/60 Hz
Connected loads
- Incandescent lamp rating 2300 W
- HV halogen lamps 2300 W
- Conventional transformers 1000 VA
- Electronic transformers 1500 W
- Fluorescent lamps, uncorrected 1200 VA
- Fluorescent lamps parallel p.f.
corrected
920 VA
- Fluorescent lamps in DUO circuit 2300 VA
Extension units
- Number of motion detector
extension unit inserts
10
- Number of mechanical
pushbuttons
Unlimited
- Maximum cable length (total) 100 m
Note Section Page
Switching commands are issued by
the release of the plug-on motion
detector top or by an extension unit.
For further details of tops, see ...
Technical Information /
Motion Detectors /
Motion detector relay
inserts
16/46
Note
Download the operating and mounting instructions from:
http://support.automation.siemens.com/ww/view/en/5tc1500/all
Motion detector triac inserts
Flush-mounting inserts for motion detector tops for switching
- 230 V incandescent lamps,
- 230 V halogen lamps and
- LV halogen lamps with magnetic transformer
The lamp is switched on using a gentle soft start
For tops see section Page
Design / i-system / Motion Detectors
Design / DELTA prol/Motion Detectors
Design / DELTA style/Motion Detectors
Technical specications
Rated voltage, 2-conductor-
connection
230 V AC, 50/60 Hz
Connected loads
- Incandescent lamp rating 40 ... 400 W
- HV halogen lamps 40 ... 400 W
- Conventional transformers
including power loss
Max. 400 VA
Short-circuit protection
- Miniature fuse T 1.6 H 250 V
Extension units
- Number of motion detector
extension unit inserts
10
- Number of mechanical
pushbuttons
Unlimited
- Maximum cable length (total) 100 m
Note Section Page
Switching commands are issued by
the release of the plug-on motion
detector top or by an extension unit.
For further details of tops, see ...
Technical Information /
Motion Detectors /
Motion detector triac
inserts
16/47
Note
Download the operating and mounting instructions from:
http://support.automation.siemens.com/ww/view/en/5tc1501/all
2/23
5/18
6/20
2/23
5/18
6/20