Motion Detectors
Inserts
10
Version Order No.
5TC1502
5TC1502
Motion detector extension unit inserts
• Flush-mounting inserts for motion detector tops
• The motion detector extension unit insert is a 3-wire extension unit that can
only be used in combination with a motion detector relay insert or a motion
detector triac insert.
• In case of a motion detection, a brightness-independent switching signal is
issued to the center unit.
• The minimum time between the two switching signals of the motion detector
extension unit insert is approx. 5 sec.
• The evaluation is performed in the top of the center unit.
• Th
e motion detector extension unit must not be assigned to more than one
center unit.
• It is not suitable for the direct switching
of loads.
For tops see section Page
• Design / i-system / Motion Detectors
• Design / DELTA profil/Motion Detectors
• Design / DELTA style/Motion Detectors
Technical specifications
• Rated voltage 230 V AC, 50/60 Hz
N conductor required
• Connection To the center unit with motion
detector top
• Possible inserts for the center unit Motion detector relay inserts
(5TC1 500)
Motion detector triac inserts
(5TC1 501)
• Extension units
- Number of motion detector
extension unit inserts
10
- Maximum cable length (total) 100 m
Note Section Page
Switching commands are issued by
the release of the plug-on motion
detector top or by an extension unit.
For further details of tops, see ...