User Manual

16/16
Siemens ET D1 · 2018/2019
16
Technical Information
Dimmers
Universal dimmer sys inserts (5TC1230)
Technical specifications
Power supply Mains connection 230 V (2-wire method),
rated voltage: 230 V AC, 50 Hz
Protection against short-circuits
In the event of a short-circuit, the universal dimmer switches off.
As soon as the short-circuit is eliminated (voltage recovery), the universal dimmer automatically switches
back on at the brightness value last set prior to the short-circuit.
Protection against overloads
In the event of an overload, and if the maximum permissible temperature is exceeded, the universal dim-
mer switches off for at least two minutes.
As soon as the device has cooled down, it is automatically switched to the current setpoint value
Load output
Number 1
Rated voltage
230 V AC, 50 Hz
Rated load
(up to 25 °C ambient temperature)
- Incandescent lamp rating 50 … 420 W
- Conventional transformers
50 … 420 VA
- Electronic transformers
70 … 420 VA
- Mixed loads
Only permissible between incandescent lamp ratings and electronic transformers
- Maximum connected load at ambient tempera-
ture
Behavior on system voltage recovery After system voltage recovery, the DELTA sys universal dimmer insert switches to the same dimming
value set prior to mains failure,
whereby the DELTA sys universal dimmer insert automatically learns the load.
A brief ickering indicates that the learning procedure is running
Terminals
The terminals for the DELTA universal dimmer sys insert comprise three screw terminals,
the following conductor/cross-sections are permissible:
0,5 … 2.5 mm² solid
0,5 … 1.5 mm² nely stranded with end sleeve without insulating collar (gas-tight crimp connection)
Caution: If the conductors need to be looped through, only conductors with max. 1.5 mm² can be used
Mechanical specications
Enclosure Plastic
Dimensions
Modular width: 71 mm x 71 mm
mounting depth: 32 mm
Weight
Approx. 70 g
Fire load
Approx. 1000 kJ
Mounting
Installation in device boxes 60 mm Ø, 40 mm deep according to DIN 49073-1
Electrical safety
Pollution degree (acc. to IEC 60664-1) 2
Degree of protection (acc. to EN 60529)
IP20
Overvoltage category (acc. to IEC 60664-1)
III
Standard
According to EN 50090-2-2 and EN 60669-2-1
EMC requirements
According to EN 50090-2-2, EN 60669-2-1, EN 61000-6-3, EN 61000-6-1
Environmental specications
Resistance to climate EN 50090-2-2
Ambient operating temperature
-5 … +45 °C
Storage temperature
-25 … +70 °C
Relative humidity (non-condensing)
5 ... 93 %
Approvals
VDE certication
I2_08607a
0 20 40 60
20
0
40
60
80
100
Ambient temperature [ °C]
Relative connected load [%]
Warning:
The connected load must
be reduced by 20 %,
depending on operating
conditions
For mounting on wood,
Rigips, gas concrete or
cavity walls
For installation in multiple
combinations or surface-
mounting enclosures