User Manual

16/19
Siemens ET D1 · 2018/2019
16
Technical Information
Dimmers
Incandescent lamp dimmers, 50 to 600 W, for two-way switching (5TC8257)
Technical specifications
Schematics
Power supply Mains connection 230 V (2-wire method), rated voltage: 230 V AC, 50/60 Hz
Protection against short-circuits
Fuse A1 (the fuse holder contains a spare fuse)
Protection against overloads
With additional temperature cutout, which permanently shuts down the dimmer in the event of an
overload
Load output
Number Two terminals for two-way switching ( and )
Rated voltage 230 V AC, 50/60 Hz
Rated load (up to 35 °C ambient temperature)
- Incandescent lamps 50 ... 600 W
- HV halogen lamps 50 ... 600 W
- Note Only incandescent lamps and/or HV halogen lamps may be connected
- Maximum connected load at ambient temperature
Warning:
The connected load must be
reduced by 20 %, depending
on operating conditions
For mounting on wood,
Rigips, gas concrete or
cavity walls
For installation in multiple
combinations or surface-
mounting enclosures
Terminals
Four screw terminals with anti-slip body. The two L-connection terminals are internally bridged
(same potential), the following conductor/cross-sections are permissible:
0,5 ... 4.0 mm² solid
0,5 ... 2.5 mm² nely stranded, with or without end sleeve (without insulating collar, gas-tight crimp
connection)
Mechanical specications
Enclosure Plastic
Dimensions Modular width: 71 mm x 71 mm mounting depth: 32 mm
Weight Approx. 95 g
Fire load Approx. 1000 kJ
Mounting Installation in device boxes 60 mm Ø, 40 mm deep according to DIN 49073-1
Electrical safety
Pollution degree (acc. to IEC 60664-1) 2
Degree of protection (acc. to EN 60529) IP20
Overvoltage category (acc. to IEC 60664-1) III
Standard According to EN 60669-2-1
EMC requirements According to EN 60669-2-1, EN 61000-6-3 and EN 61000-6-1
Environmental specications
Ambient operating temperature –5 ... +45 °C
Storage temperature –25 ... +70 °C
Relative humidity (non-condensing) 5 ... 93 %
Approvals VDE certication and KEMA certication
I2_11961
-10 20 40 60
20
0
40
60
80
100
800
100
Ambient temperature [°C]
Relative connected load [%]
L
PE
N
L
1
2
3
I2_11963a
1
2
3
4
5
4
5
Fuse holder with fuse T 2.5 H 250 V
Outer conductor connection
Load connection / corresponding conductor
Load connection / corresponding conductor
Trimpotentiometer for basic brightness
230 V AC ~
3
4
1