User Manual

16/21
Siemens ET D1 · 2018/2019
16
Technical Information
Dimmers
LV dimmers, for electronic transformers, 20 to 315 W (5TC8262)
Technical specifications
Schematics
20 ... 315 W
20 ... 315 W
20 ... 315 W
I201_11961
-10 20 40 60
20
0
40
60
80
100
800
100
Umgebungstemperatur [°C]
relative Anschlussleistung [%]
Power supply
Protection against short-circuits
Protection against overloads
Load output
Number
Rated voltage
Rated load (up to 35 °C ambient temperature)
- Incandescent lamps
- HV halogen lamps
- LV halogen lamps with electronic transformer
- Note
- Maximum connected load at ambient temperature
Two terminals for two-way switching ( and )
230 V AC, 50 Hz
L
5TC8 258
PE
N
L
1
2
I2_12395
1
2
3
3
4
4
Outer conductor connection
Load connection / corresponding conductor
Load connection / corresponding conductor
Trimpotentiometer for load balancing
230 V AC ~
Terminals 4 screw terminals with anti-slip terminal body, the following conductor/cross-sections are permissible:
0,5 ... 4.0 mm² solid
0,5 ... 2.5 mm² nely stranded, with or without end sleeve (without insulating collar, gas-tight crimp
connection)
Mechanical specications
Enclosure Plastic
Dimensions Modular width: 71 mm x 71 mm, mounting depth: 32 mm
Weight
Approx. 95 g
Fire load Approx. 1000 kJ
Mounting Installation in device boxes 60 mm Ø, 40 mm deep according to DIN 49073-1
Electrical safety
Pollution degree (acc. to IEC 60664-1) 2
Degree of protection (acc. to EN 60529) IP20
Overvoltage category (acc. to IEC 60664-1) III
Standard According to EN 60669-2-1
EMC requirements According to EN 60669-2-1, EN 61000-6-3 and EN 61000-6-1
Environmental specications
Ambient operating temperature –5 ... +45 °C
Storage temperature –25 ... +70 °C
Relative humidity (non-condensing) 5 ... 93 %
Approvals VDE certication
Mains connection 230 V (2-wire method), rated voltage: 230 V AC, 50 Hz
Reversible operating electronic fuse
With additional temperature cutout, which shuts down the dimmer in the event of an overload and only
resupplies it automatically with power when the overload
cooled down
Does not support connection of:
Energy-saving lamps
Magnetic transformers
Warning: The connected load must be
reduced by 25 %, depending on oper-
ating conditions
For mounting on wood, Rigips, gas
concrete or cavity walls
For installation in multiple combina-
tions or surface-mounting enclosures
If using highly thermally insulating
materials (e.g. glass wool), it may be
necessary
to reduce the connected
load even further
2 3